1. DESCRIPTION
These general purpose, one input rate totalisers are
primarily
intended for
use with pulse output
flowmeters. The instruments simultaneously display
the rate of flow and the total flow in the same or
different engineering units on two separate displays.
They are controlled and configured via the four front
panel push buttons, a user defined four digit code
may be entered to prevent accidental access to the
instrument's configuration menu.
The two models are electrically similar, but have
different size displays and enclosures. The available
factory fitted accessories also vary.
Model Displays Bezel size
BA537E
8 digits 9mm high 96 x 48mm
6 digits 6mm high
BA538E
8 digits 18mm high 144 x 72mm
6 digits 12mm high
This instruction manual supplements the abbreviated
instruction sheet supplied with each instrument.
2. OPERATION
Fig 1 shows a simplified block diagram of the BA537E
and BA538E Rate Totalisers. The instruments can
accept pulses from most types of flowmeter
transducers.
When connected to a pulse output
flowmeter the BA537E and BA538E will provide an
accurate display of the rate of flow and the total flow
in the same or different engineering units.
The
internal lineariser, which can have up to sixteen
straight-line
segments,
may
be
calibrated
to
compensate for flowmeter non-linearity.
The BA537E and BA538E have a single pair of input
terminals for connection to all types of transducer.
When counting pulses from a transducer requiring
energising, such as a switch contact, open collector or
a two wire proximity detector, an external link between
terminals 3 and 4 supplies power to the transducer
input terminals.
Factory fitted accessories include an internally
powered display backlight, dual alarms and an
isolated 4/20mA output which may be configured to
retransmit the rate or total display.
The larger BA538E Rate Totaliser is always supplied
with an isolated pulse output which can be
configured to synchronously retransmit the pulse
input, or the flow total. This output is only available
on the smaller BA537E Rate Totaliser as an option.
Factory fitted optional accessories for the two
models are shown below:
BA537E BA538E
96 x 48mm 144 x 72mm
Backlight Backlight
Isolated dual alarms
*
Isolated
dual alarms
or
Isolated
4/20mA output
*
Isolated
4/20mA output
or
Isolated pulse output
*
*Only one output option
Isolated pulse output
may be fitted to BA537E always fitted to BA538E
Fig 1 BA537E and BA538E block diagram
2.1 Initialisation
Each time power is applied to the Rate Totaliser
initialisation is performed. After a short delay the
following display sequence occurs:
All segments of the display are activated
Instrument
starts
functioning
using
the
configuration information stored in permanent
memory.
Unless total and grand total
displays have been reset to zero, new flow will
be added to the existing totals.
3