background image

Appendix  

Operating manual AVERO Motion  

V2.6 E 

Page 36 of 48   

13.4 Declaration of Conformity 

 

 
 

 

Содержание AVERO Motion

Страница 1: ...AVERO Motion Avero Motion Avero Motion E Version 2 6 E Subject to technical modifications 2018 12 19 Operating manual Original operating manual...

Страница 2: ...st of used safety instructions 9 4 5 Warnings 10 5 Transport 11 5 1 Unpacking the product 11 5 1 1 Removing the cardboard 12 5 1 2 Loosening the product from the pallet 12 6 Installation 12 6 1 Electr...

Страница 3: ...e 29 13 Appendix 31 13 1 Technical data 31 13 2 Dimensions AVERO Motion Tilt and Reclining Bath Tubs 32 13 3 Wiring Diagram 33 13 3 1 Connection at the side 33 13 3 2 Connection at the rear 34 13 3 3...

Страница 4: ...ured and tested according to stringent quality criteria 1 2 Manufacturer s address BEKA Hospitec GmbH Am R benmorgen 3 35582 Wetzlar Phone 49 0 641 9 22 22 0 Fax 49 0 641 9 22 22 20 info beka hospitec...

Страница 5: ...ll as the national regulations laws and prescriptions related to work safety and accident prevention The manufacturer of the product is only responsible for the safety and the reliability of the produ...

Страница 6: ...ssembly of individual components of the product Please read the operating manual and the safety instructions before starting to use the product Keep the operating manual near the device for future ref...

Страница 7: ...V2 6 E Page 7 of 48 3 4 Descriptions of the various models AVERO Motion 11 button control panel tub spout and thermostat mixer Optional with 10 button hand control AVERO Motion E Without control pane...

Страница 8: ...tending physician 4 2 Other prescriptions The product meets the current VDE prescriptions 0100 and 0100 710 However have a specialist company check the compliance of your electrical installation with...

Страница 9: ...to DIN EN 60601 1 Special waste no household waste The device and the packaging materials never must be disposed of in the domestic waste stream CE label in accordance with the EC Directive on Medica...

Страница 10: ...ng cable so that they cannot be damaged Damaged mains cables could cause fire or lead to electrocution and must not be used The caregivers must protect their skin and eyes against concentrated disinfe...

Страница 11: ...lity of the manufacturer for resulting damage For damages resulting from the use of spare parts or accessories not approved by the manufacturer any further liability of the manufacturer is excluded 5...

Страница 12: ...m After all fixations have been removed you can lift the bath tub from the pallet 2 persons The accessories for your bath tub are included in the supplied cardboard box 6 Installation The bath tub is...

Страница 13: ...anger of tripping The AVERO Motion is connected to the power supply network through a shock proof protective socket featuring the legally prescribed splash guard IP class 230 V AC 50Hz 3 x 1 5 mm 1 5...

Страница 14: ...t scalding the hot cold water mixer must be set up in accordance with the local water supply prior to the first use The settings must be documented NOTE In order to ensure a safe functioning and opera...

Страница 15: ...panel 9 Disinfection handheld showerhead optional 2 Water consumption 10 MP3 docking station optional 3 Thermostat knob 11 Aroma system optional 4 Ball joint wall bracket 12 Foot stand 5 Handheld show...

Страница 16: ...ht adjustment button DOWN 10 Disinfection button 3 Air spa system button on off 11 Power Function LED 4 Increase intensity of air spa 12 Handheld showerhead button 5 Reclining adjustment button UP 13...

Страница 17: ...he control variant the settings for scalding protection are displayed for approx 1 5 seconds The display 3 14 shows hot the display 1 15 the set temperature of the scalding protection for the hand sho...

Страница 18: ...to start the water flow By turning the rotary knob to change over you can toggle between the bath spouth and the hand shower Your fitting is equipped with an Eco function The flow rate of the hand sh...

Страница 19: ...the automatic water stop option you must turn off the filling of the tub manually Press this button If you do not manually turn off the filling of the tub the water will overflow Water will keep runn...

Страница 20: ...system please also refer to the enclosed operating manuals 8 Operation AVERO Motion s concept is to facilitate bathing or showering to promote the patient s mobility and provide the opportunity to en...

Страница 21: ...button If your tub is equipped with the optional automatic water stop function the filling will automatically stop when it reaches the fill level If your tub does not have this option interrupt the fi...

Страница 22: ...tween the door and the tub body These parts could get caught and injure the patient Pull the door to up to approx 15 cm in front of the lock and check the position of the locking lever If the door han...

Страница 23: ...t the tub by pressing the button until the motor shuts itself off To refill the tub press the control button When the water has reached the selected level filling will automatically stop This feature...

Страница 24: ...uide the tub down to the bottom entry height level Press this button and hold the button down until the travel movement is automatically switched off Note Open the door only when there is no water in...

Страница 25: ...b or use a lift system to ease the patient out of the tub Note Make sure that the tub is always disinfected and rinsed before using it for the next patient Please make use of the integrated disinfecti...

Страница 26: ...that all warranty claims regarding surface damage will not be accepted if aggressive cleaning agents are anyhow used 9 2 Disinfecting the bath tub You must carefully disinfect and rinse your bath tub...

Страница 27: ...y equipment which is used in special locations or installations an annual check to the DGUV German Statutory Accident Insurance Association Prescription 3 BGV A3 must be carried out on the AVERO Motio...

Страница 28: ...mponents must be recycled in accordance with the WEEE 11 2 Disposal of the product The expected service life of the bath tub is approx 8 years At the end of the product s lifetime contact your BEKA de...

Страница 29: ...er situated in the water inlet The automatic filling is not working Disconnect the bath tub from the power supply Perform restart If no result is obtained contact the service after sales service Only...

Страница 30: ...s not working a Check whether the USB stick is correctly inserted The USB stick might be defect Insert a new USB stick The colour light therapy is not working a Main board defect Inform the after sale...

Страница 31: ...without packaging ca 175 kg Pre fill capacity 98 l Fill weight without patient ca 270 l Tub drainage liter per minute 75 l Water consumption patient 185 l Patient weight max 220 kg SWL safe load 350...

Страница 32: ...Appendix Operating manual AVERO Motion V2 6 E Page 32 of 48 13 2 Dimensions AVERO Motion Tilt and Reclining Bath Tubs...

Страница 33: ...Appendix Operating manual AVERO Motion V2 6 E Page 33 of 48 13 3 Wiring Diagram 13 3 1 Connection at the side...

Страница 34: ...Appendix Operating manual AVERO Motion V2 6 E Page 34 of 48 13 3 2 Connection at the rear...

Страница 35: ...Appendix Operating manual AVERO Motion V2 6 E Page 35 of 48 13 3 3 Connection at the floor...

Страница 36: ...Appendix Operating manual AVERO Motion V2 6 E Page 36 of 48 13 4 Declaration of Conformity...

Страница 37: ...76 Color light system 910150585 Cleaning system 910150580 Cleaning system 910150586 Second showerhead holder 910150586 Second showerhead holder 910150587 Emergency function in case of power failure 91...

Страница 38: ...se Picture 3 The picture shows the unscrewed handheld shower Assembly of the handheld shower is done in the reverse order 13 7 2 Changing the shower hose Picture 1 und 2 Pictures 1 and 2 show the show...

Страница 39: ...lder Picture 5 Now remove the holder from the handheld shower and replace with a new one Assembly of the handheld shower holder is done in the reverse order 13 7 4 Changing the disinfectant shower hea...

Страница 40: ...nd overflow Picture 1 The picture shows the eccentric cover Picture 2 To loosen the cover pull it in an upward direction Picture 3 The picture shows the removed cover Picture 4 The rotary actuation mu...

Страница 41: ...r listed ELECTROMAGNETIC ENVIRONMENTS The customer or the user of the AVERO Motion must ensure that the appliance is used in such environment Emission measurements Compliance Electromagnetic environme...

Страница 42: ...ality of the supply voltage should match that of a typical business or hospital environment Overvoltage IEC 61000 4 5 1 kV cable against cable 2 kV cable against ground connection 1 kV cable against c...

Страница 43: ...of fixed HF transmitters as determined by an electromagnetic field survey a should be less than the COMPLIANCE LEVEL in each frequency range b In the vicinity of equipment marked with the following s...

Страница 44: ...stance depending on the transmitting frequency in m 150 kHz to 800 MHz d 0 35 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 1 1 10 100 0 04 0 11 0 35 1 1 3 5 0 12 0 38 1 2 3 8 12 0 23...

Страница 45: ...enmorgen 3 35582 Wetzlar Serial number _____________________________________________ Date of purchase _____________________________________________ Site _____________________________________________ C...

Страница 46: ...Appendix Operating manual AVERO Motion V2 6 E Page 46 of 48 Periodic inspection repair DGUV 3 safety check etc Type of inspection Date Result Measure Signature...

Страница 47: ...Appendix Operating manual AVERO Motion V2 6 E Page 47 of 48 Your notes...

Страница 48: ...BEKA Hospitec GmbH Am R benmorgen 3 35582 Wetzlar Germany Phone Fax 49 0 6 41 9 22 20 0...

Отзывы: