1 691 626 220
2015-08-05
|
Beissbarth GmbH
Technical data | SA / SN 6xx | 15
en
7.
Technical data
7.1
Ambient conditions
Designation
Value
Operating temperature
-10…+50 °C
Storage temperature
-10…+50 °C
Relative humidity
(no condensation)
< 85 %
7.2
SA 640
Measurement system:
Designation
Value
Measurement system
Bending bar with strain
gauge
Basic data:
Designation
Value
Dimensions (L x W x H)
440 x 2360 x 280 mm
Shaker plate dimensions (L x W)
690 x 273 mm
Maximum test width
2200 mm
Minimum test width
820 mm
Weight approx.
260 kg
Permissible test load per axle
2000 kg
Max. permissible driveover load per
axle
4000 kg
Workplace emission sound pressure
level as
≤ 70 dB(A)
Degree of protection (as per
DIN 40 050)
IP 54
Operating data:
Designation
Value
Power supply
3 x 230 VAC / 11,4A / 50-60Hz
3 x 400 VAC / 6,6A / 50-60Hz
Fuse protection (customer)
3 x 20 A / C 3-pole (230 V)
3 x 20 A / C 3-pole (400 V)
Supply cable (customer)
4 x 2,5 mm (230V)
5 x 2,5 mm (400 V)
Rated power of drive motors
2 x 2,5 kW
Motor speed
1360 1/min
cos
f
of motors
0,75
Max. test frequency
25 Hz
Stroke
6 mm
7.3
SN 680
Measurement system:
Designation
Value
Measurement system
Bending bar with strain
gauge
Basic data:
Designation
Value
Dimensions (L x W x H)
440 x 2360 x 280 mm
Shaker plate dimensions (L x W)
690 x 273 mm
Weight approx.
270 kg
Maximum test width
2200 mm
Minimum test width
820 mm
Permissible test load per axle
1650 kg
Max. permissible driveover load per
axle
4000 kg
Workplace emission sound pressure
level as
≤70 dB(A)
Degree of protection (as per
DIN 40 050)
IP 54
Operating data:
Designation
Value
Power supply
(via master switch box)
3 x 230 VAC / 14,2A / 50-60Hz
3 x 400 VAC / 8,2A / 50-60Hz
Fuse protection (customer)
3 x 20 A / C 3-pole (230 V)
3 x 20 A / C 3-pole (400 V)
Supply cable (customer)
4 x 2,5 mm (230V)
5 x 2,5 mm (400 V)
Rated power of drive motors
2 x 3,0 kW
Motor speed
1420 1/min
cos
f
of motors
0,7
Test frequency of suspension
tester
0…30 Hz
Noise simulator test
frequency
10…30 Hz
Cut-out limit of
overtemperature safeguard
90 °C