Setting up RUN Delay
Fixed Value (Single-step) Programs
BEING’s L Series controller allows the user to delay the
start of a program for up to 99 hours and 59 minutes.
Once the delay times out, the program will start operation.
Press the SETTING and SHIFT keys for 3 seconds to
enter the controller’s internal parameter settings.
Time area will change and fi rst digit will blink.
STEP 2:
Press SETTING key
Press the SETTING key to enter Level 1 parameters.
STEP 1:
Enter Level 1 of controller internal parameters
When entering the controller’s internal parameters, Level
1, LK =0000, will always come up fi rst.
Press the SETTING key 1 time to set
parameter dy and return to fi xed value
program standard state.
Press the INCREASE key to enter the fi rst
time value. Press the SHIFT key to move to
the second time digit. Digit will blink. Press
the INCREASE key to enter the second time
value.
Parameter
dy=00:00 to 99:59.
STEP 4:
Set parameter and return to multi-step
program standard state.