background image

Page  3

The  installation  of  the  detector  does  not  exempt  from  the  compliance  with  all  regulations  concerning  the  characteristics,
installation  and  use  of  gas  appliances.  The  ventilation  of  the  spaces  and  the  elimination  of  combustion  products  are  described
in  the  UNI  norms  according  to  ART.  3  LAW  1083  /  71  and  relevant  legal  provisions.

Compatible control units

CONTROL  UNITS

             MOUNTING

PROBES Max.    DEGREE         PRE

  ALARMS      POSITIVE      OPERATING

                                                                                                    protec.        alarms                        safety           range

GS100M  unit  1  zone             Wall/cabinet

1

IP44

2

1

YES

N O

GS300-Mc  unit  1  zone

Wall/cabinet

3

IP44

2

1

YES

N O

BX444-MC  unit  1  zone

Wall/cabinet

4

IP44

2

1

YES

N O

BX150 unit   1 zone

Panel

            1

IP42

1

1

YES

N O

BX180  unit    1  zone

Omega  bar  DIN

1

IP20

1

1

YES

N O

BX280  unit    1  zone

Omega  bar  DIN

2

IP20

1

1

YES

N O

BX449F  unit  1  zone

            Omega bar DIN

4

IP20

1

1

YES

N O

BX308 unit  1  zone

            Omega bar DIN

8

IP20

1

1

YES

YES

BX308/Box    unit  1  zone

Wall

            8

IP65

1

1

YES

YES

BX316 unit    2  zones

            Barra Omega

            16

IP20

1

2

YES

YES

BX316/Box  unit    2    zones

Wall

            16

IP65

1

2

YES

YES

TAKITJ8  *  Data  Collector

Wall

             8

IP65

-

-

-

-

MAINTENANCE

The user periodically (every 6 months) must perform a check of the operation of the control unit by spraying

a suitable test gas at the base of the probes connected until the alarm condition is reached.

• At least once a year make a more accurate check by a specialist technician.

• Disabling the detector must be carried out by qualified personnel.

The  position  of  the  probe  is  a  crucial  factor  for  a  gas  detection  unit  correct  functioning.
In  order  to  obtain  the  maximum  results  from  an  appliance  and  minimize  the  probabilities  of  false  alarms,  we
recommend  to  follow  this  diagram  and  to  keep  in  mind  the  following  general  rules.
The  remote  probe  must  be  located  at  different  heights,  according  to  the  type  of  gas.
These  heights  are:
-  30  cm  from  the  lowest  point  of  the  floor  in  order  to  detect 

 

Heavy  Gases

 

:

 

 

LPG, 

Gasoline  vapours,

Alcohol,

    white  spirit,  Ethanol,  Acetone,  Chlorine,  CO.

- 30 cm from  the highest  point  of the ceiling in  order  to detect  Light gases:

  Methane, Hydrogen, 

Ammonia,

Acetylene.
-  The  probe  should  not  be  placed  near  the  appliances  to  be  controlled  (boilers,  burners,  industrial  kitchens,
etc.)  but

    on  the  opposite  wall.

-  The  probe  should  not  be  affected  by  smoke,  vapour,  etc.  as  they  could  distort  their  measurement.  It  must
be  placed

    away  from  sources  of  heat,  suction  fans,  ventilation  fans.

Positioning of the Sensor

YES

NO !

NO !

30  cm.  Heavy  gases

Average  height  volatile  gases

30  cm.  Light  gases

Содержание SGM595

Страница 1: ...ith one of BEINAT s industrial type Control Units detects the presence of esplosive gas such as Methane LPG Hydrogen The probe is managed by a microprocessor which not only supplies an alarm signal to the control unit connected to it but also allows execution of a self diagnosis and therefore an AUTOMATIC CALIBRATION in order to always have the maximum detection accuracy The self calibration means...

Страница 2: ... gas by issuing it from a pre calibrated testing aerosol Important The test of operation and eventually offset cancellation must be performed at least once a year by a qualified technician CHECK the integrity of the unit after having removed it from the box Check that the data written on the box correspond to the type of gas used When doing the electrical connections follow the drawing closely Any...

Страница 3: ... operation of the control unit by spraying a suitable test gas at the base of the probes connected until the alarm condition is reached At least once a year make a more accurate check by a specialist technician Disabling the detector must be carried out by qualified personnel The position of the probe is a crucial factor for a gas detection unit correct functioning In order to obtain the maximum r...

Страница 4: ...The probe detects an anomaly FAULT 1 2 3 4 5 6 C NO C NO C NO Fault Relay Pre Allarme Relay Pre Allarme Relay Optional Relay Card CARD03 Linear Output 4 20 mA 100 20 100 20 SELECTION OF THE OPERATING RANGE The SGM595 Conventional Probes NOT SUITABLE IN ATEX ZONE LEAVE THE FACTORY WITH A DEFAULT OPERATING RANGE VALUE SET AT 20 OF THE LEL To select the operation range to 100 LEL you need to move the...

Страница 5: ...mise the safety of the survey If the device does not start up Check that the 12 24 Vdc power is present and that positive and negative polarity has not been inverted If the Fault LED lights up Check that the cables are connected according to the drawing and that the wire isolation sheath has not been pinched Check the voltage at the terminals 1 2 It must be higher than 10 80 Vdc and lesser than 26...

Страница 6: ...nce and gas sensor replacement Detectiondiagrams data ppm 0 50 100 150 200 250 300 6 7 Toxic Gas Detection diagram 0 4 5 10 15 20 7 2 20 m A Linear 5 Zona Avaria 9 3 12 14 6 17 3 Explosive Gas Detection diagram 0 4 8 12 16 20 0 4 5 10 15 20 7 2 10 4 13 6 16 8 20 m A Linear 5 L I E Zona Avaria The installation of the SGM595 probe its ordinary and extraordinary maintenance and its out of service rem...

Страница 7: ... stops its cause must be found and the relevant consequent measures taken If the alarm continues and the cause of gas presence cannot be found or removed abandon the building and call the emergency services when outside fire department distributors etc IMPORTANT The operation test should not be carried out with the gas tap as this does not guarantee a sufficient concentration to activate the gener...

Страница 8: ...shall be excluded from the warranty BEINAT S r l is not liable for possible damage direct or indirect to people animals or things from product faults and from its enforced suspension of use DISPOSAL OF OLD ELECTRICAL ELECTRONIC EQUIPMENT This symbol on the product or its packaging to indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicab...

Отзывы: