The SG580  is born from the elegance and prestige that has always distinguished  BEINAT S.r.l. and from the home
fitness  concept.
The  probe is a Catalytic gas detection unit with IP66 protection (NO ATEX) that, together with one of BE INAT’s
industrial type Control Units, detects the presence of esplosive gas such as Methane, LPG, Hydrogen, and other
types of gas.
The probe is managed by a microprocessor which not only supplies an alarm signal to the control unit connected
to it, but  also allows execution of a self-diagnosis and therefore an AUTOMATIC  CALIBRATION,

 

in order to always

have the maximum detection accuracy.
The self-calibration means the probe adapts in harsh and variable temperature environments, avoiding false alarms
due to anomalous events.
The probe has a 0 ÷ 20 % LEL linear output conforming to the 4 ÷ 20mA standard, for which can be connected
with one of BEINAT's industrial control units.
The important innovation of this probe is:
The possibility to substitute the sensor at the end of the operating cycle or fault by the technician without having
to send to BEINAT Srl.

CONFORMITY

Installation and user
guide

Important: Assembly / maintenance of the appliance must be carried out by qualified personnel and in
accordance with applicable laws and regulations.
The manufacturer assumes no responsibility for the use of products that have to comply with particular
environmental and / or installation standards.

Important note
Before connecting the equipment, it is recommended that you read the instruction manual carefully and
keep it for future reference. It is also recommended to perform the electrical connections correctly as
per enclosed drawings, observing the instructions and the Standards.
N.B. Refer to the documentation in all cases where the symbol is on the side

EN 50270

Compliant  EN 60079-29-1

Reports issued by  TUV Italia

Channel:  Beinat  gas  solutions

Electric connections also available on

Indispensabile instrument for the annual check of the probes
Instrument  of  testing  TS1008
To  facilitate  the  reading  of  the  functional  parameters  of  the  probe  as  well  as  the  control  of
annual  operating,  the  BEINAT  S.r.l.  has  built  a  new  portable  tester  TS1008.
The tester allows to read all the data in the memory of the probes eand by serial transmission,
it prints the ticket that  confirms the testing data.

Conventional Gas Sensor SG580

V. R0

Not applicable for ATEX zone

Содержание SG580

Страница 1: ...CONFORMITY Installation and user guide Important Assembly maintenance of the appliance must be carried out by qualified personnel and in accordance with applicable laws and regulations The manufacturer assumes no responsibility for the use of products that have to comply with particular environmental and or installation standards Important note Before connecting the equipment it is recommended tha...

Страница 2: ...on of the SG580Sensor its ordinary and extraordinary maintenance every six months and its out of service removal at the end of the functional life guaranteed by the manufacturer must be carried out by authorized or specialized personnel Do not allow it to become wet The control unit can be seriously damaged as it is not waterproof either when immersed in water or exposed to high levels of humidity...

Страница 3: ...unit 1 zone Panel 1 IP42 1 1 YES NO BX180 unit 1 zone Omega bar DIN 1 IP20 1 1 YES NO BX280 unit 1 zone Omega bar DIN 2 IP20 1 1 YES NO BX449F unit 1 zone Omega bar DIN 4 IP20 1 1 YES NO BX308 unit 1 zone Omega bar DIN 8 IP20 1 1 YES YES BX308 Box unit 1 zone Wall 8 IP65 1 1 YES YES BX316 unit 2 zones Barra Omega 16 IP20 1 2 YES YES BX316 Box unit 2 zones Wall 16 IP65 1 2 YES YES TAKITJ8 Data Coll...

Страница 4: ...etylene The probe should not be placed near the appliances to be controlled boilers burners industrial kitchens etc but on the opposite wall The probe should not be affected by smoke vapour etc as they could distort their measurement It must be placed away from sources of heat suction fans ventilation fans Positioning of the Sensor Detectiondiagrams data ppm 0 50 100 150 200 250 300 6 7 Toxic Gas ...

Страница 5: ... the operating range to 100 LEL you need to move the jumper between the central and the top pole Electrical cabling Please read the paragraph Particular Specifications for Use in Explosive Atmospheres NOTE Please remind that if you pierce the FLAMEPROOF container it will completely lose its properties Moreover you should install a FLAMEPROOF cable gland for the connection cables 3 2 1 1 2 3 4 5 6 ...

Страница 6: ...not been pinched Check the voltage at the terminals 1 2 It must be higher than 10 80 Vdc and lesser than 26 4 Vdc Check that the connector of the sensor is correctly inserted If it s connected to control unit Check the voltage at the terminals 2 3 It must be from a minimum of 0 8 Vdc to a maximum of 1 1 Vdc Remark If the probes are connected to the control units BX308 and BX316 the voltage at the ...

Страница 7: ...electrical device or appliance 4 Open windows and doors in order to increase ventilation If the alarm stops its cause must be found and the relevant consequent measures taken If the alarm continues and the cause of gas presence cannot be found or removed abandon the building and call the emergency services when outside fire department distributors etc IMPORTANT The operation test should not be car...

Страница 8: ...l is not liable for possible damage direct or indirect to people animals or things from product faults and from its enforced suspension of use DISPOSAL OF OLD ELECTRICAL ELECTRONIC EQUIPMENT This symbol on the product or its packaging to indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electr...

Отзывы: