Components and commands

1)  MAINS  connected  indication  LED.  When  the  green  LED  is  blinking,  the  GS920  performs  a  test  of
the  sensor’s  efficiency  status,  and  gets  it  to  the  functioning  temperature.  This  phase  lasts  about  60
seconds.  At  the  end,  the  LED  stops  blinking  and  the  green  light  remains  ON.
During the test period, the GS920 does not detect the gas.
2)
  FAULT  and  functional  life  wear  indication  LED.
If  this  LED  turns  on,  it  means  that  the  gas  detection  catalytic  sensor  is  not  working  efficiently  and
must  be  replaced  by  an  authorized  technician.
The sensor duration is  guaranteed for 6  years (in clean air). After six years, the yellow LED will start
a  quick  blinking.  You  will  hear  a  short  beep  every  hour.
3) ALARM  indication LED.  This LED  turns on  when room  gas  concentration  exceeds the  danger level,
at 10% of  L.E.L.

4)  Micro  switches:
Switch 1:  Positioning the switch to ON – Intrinsically safe operation – the relay is excited at the
end  of  the  latency  time  and  switches  on  each  alarm.
Positioning  the  switch  to  OFF  –  Normal  operation  –  the  relay  switches  on  each  alarm.
Switch 2: Positioning the switch to ON, the relay is set to impulse functioning. Each pulse lasts about
30  seconds.
Positioning  the  switch  to  OFF,  the  relay  goes  in  continuous  functioning  mode,  until  the  gas  threshold
drops  under  the  danger  level.

5)  Catalytic  sensor  for  Methane  or  LPG  explosive  gas  detection.
6)  TEST  button.  This  button  is  used  to  simulate  a  gas  leak,  after  installation.
7)  RESET  button.  This  button  is  used  to  stop  the  alarm,  when  triggered  by  an  EARTHQUAKE.
8)  Identification  label,  registration  number  and  manufacturing  year,  located  under  the  ABS  small
dome.
9)  TEST  POINT  for  testing.  It  is  used  in  the  laboratory  or  by  a  qualified  technician.

10)

Label  of  the  gas  sensor  expiration  date.

This label should be applied by the technician during installation, keeping in mind that the detector
should be overhauled after 5  years.

Содержание GS920

Страница 1: ...an activate solenoid valves sirens and any other alarm signal device The micro switch makes it possible to select the relay impulse functioning to connect manual reset solenoid valves or the continuous functioning and to activate N C class A solenoid valves and sirens Another micro switch allows turning on off the Intrinsic Safety The power supply unit allows driving of a manual reset solenoid val...

Страница 2: ...traordinary maintenance and its out of service removal at the end of the functional life guaranteed by the manufacturer must be carried out by authorized and or specialized personnel Do not allow it to become wet The detector can be seriously damaged when immersed in water Remember that the probe has an IP30 protection degree Do not drop it Heavy knocks or falls during transportation or installati...

Страница 3: ...er level at 10 of L E L 4 Micro switches Switch 1 Positioning the switch to ON Intrinsically safe operation the relay is excited at the end of the latency time and switches on each alarm Positioning the switch to OFF Normal operation the relay switches on each alarm Switch 2 Positioning the switch to ON the relay is set to impulse functioning Each pulse lasts about 30 seconds Positioning the switc...

Страница 4: ...Pagina 4 34 mm 50 mm Embedded box 503 70 mm 105 mm 5 mm 115 mm 84 mm 115mm Dimensions ...

Страница 5: ... its measurement It should be located away from sources of heat ventilators or fans It must not be installed on a wall in plasterworch It must be installed only on walls in masonry Once the device has been turned on the MAINS LED will start blinking for about 60 seconds after which it will remain ON Now the GS920 is ready for detection of explosive gas After 24 hours from installation begin the se...

Страница 6: ...les cornices also unbraced parapets and architectural ornaments Some cracks in masonry C Waves on ponds water turbid with mud Small slides and caving in along sand or gravel banks Large bells ring Concrete irrigation ditches damaged Steering of motor cars affected Damage to masonry C partial collapse Some damage to masonry B none to masonry A Fall of stucco and some masonry walls Twisting fall of ...

Страница 7: ...ndon the building and call the emergency services when outside fire department distributors etc If the device does not start up Check that the 230V power is correctly connected If the fault LED lights up If the YELLOW LED is remains ON check the detection capsule status It is probably faulty and has to be replaced Call an authorized technician If the detector is repeatedly issuing an alarm Check t...

Страница 8: ...tion Scheme of GS920 Detector N C C NO N Ph 12 V 1 2 3 4 5 6 7 8 Without Intrinsic Safety With Intrinsic Safety Normally closed electrovalve 230VAC The Relay is free of voltage Range of relay contact 10A resistive The electrovalve is a N C Automatic or manual retrig Note To connect a N O Electrovalve swap the connections between pin 8 and 6 The Relay is free of voltage Range of relay contact 10A r...

Страница 9: ... free of voltage Range of relay contact 10A resistive The drawn electrovalve is a Normally Open type with manual reset and with a power supply of 12V 600mA MAX The activation is impulsive Power Supply 230 V AC Normally open electrovalve 230V AC with intrinsic safety Ph N 1 2 3 4 5 6 7 8 The Relay is free of voltage Range of relay contact 10A resistive The drawn electrovalve is a N C type with manu...

Страница 10: ...open electrovalve 230V AC without intrinsic safety The Relay is free of voltage Range of relay contact 10A resistive The drawn electrovalve is a Normally Open type with manual reset and with a power supply of 12V 600mA MAX The activation is impulsive Power Supply 230 V AC Electricalconnections ...

Страница 11: ...Page 11 Note ...

Страница 12: ... 3 years from manufacturing date in agreement with the following conditions The components acknowledged as faulty will be replaced free of charge excluding the replacement of plastic or aluminium cases bags packing batteries and technical reports The device must arrive free of shipment charges to BEINAT S r l Defects caused by unauthorized personnel tampering incorrect installation and negligence ...

Отзывы: