GB
Controller
SV1-2-10Z
GB_SV1-2-10Z.DOC 1003
BEIER-Electronic
18
Technical Description
Menue line ‚H‘
Input
Output
H T 4 4 = • 0 7 , 5 • 1 1 , 8
Rise-delay time
Down-delay time
In Menue line ‚H‘ the rise-delay time and down-delay time of the time function
element T44 is set. Values between 0,0 and 25,0 seconds are possible. The in- and
output of the time function element is represented by a dot in front of the number.
Key functions
Key
(Menue)
By means of this key it is possible to page among the different menue lines. Upon
each key actuation a jump to the next menue line is executed (A
Æ
B
Æ
C
Æ
D
Æ
E
Æ
F
Æ
G
Æ
H
Æ
A)
Menue line ‚A‘
Set-point values / measured current
Menue line ‚B‘
Maximum output current
Menue line ‚C‘
Output frequency
Menue line ‚D‘
Soft start / soft run-out
Menue line ‚E‘
T41 ON / T41 OFF
Menue line ‚F‘
T42 ON / T42 OFF
Menue line ‚G‘
T43 ON / T43 OFF
Menue line ‚H‘
T44 ON / T44 OFF
Key
(Enter)
By mean of the Enter-Key a jump into the change-mode is executed. Now it is
possible to change values, this is displayed by the flashing cursor. By means of the
keys
and
the requested value can be set. Shall the new value be permanently
stored it has to be confirmed by a second pressing of the
. The change mode is
now finished. The new set value will be still available after ON/OFF of the SV1-2-10Z.
Shall the new value not be permanently stored, the change mode has to be left by
key
. The new set value remains unchanged only until the next switch OFF of the
device.
Attention: There is a possibility to lock several menue lines for the access by the
operator. A change into the change-mode is then only possible after correct enter of
a 3-digit code word.