1. INTRODUCTION

1. INTRODUCTION

Thank  you  very  much  for  expressing  your  confidence  in

BEHRINGER products by purchasing the ULTRAGRAPH DIGITAL

DEQ2496, an extremely high-quality digital equalizer with built-in

24-bit/96 kHz A/D and D/A converters, making it an ideal tool for

both live and studio applications.

In addition to graphic EQing, the ULTRAGRAPH DIGITAL gives

you  a  wide  array  of  additional  functions,  such  as  feedback

destroyer, pink noise generator, limiter/noise gate etc., leaving

no wishes open. With these and many more features the DEQ1024

is an absolutely all-purpose device for your recording or mastering

studio and will definitely upgrade your equipment.

+

The  following  user’s  manual  is  intended  to

familiarize  you  with  the  unit’s  control  elements,

so that you can master all the functions. After having

thoroughly  read  the  user’s  manual,  store  it  at  a  safe

place  for  future  reference.

1.1 Before you get started

1.1.1 Shipment

The DEQ1024 was carefully packed at the factory to assure

secure  transport.  Should  the  condition  of  the  cardboard  box

suggest that damage may have taken place, please inspect the

unit immediately and look for physical indications of damage.

+

Damaged units should NEVER be sent directly to us.

Please  inform  the  dealer  from  whom  you  acquired

the  unit  immediately  as  well  as  the  transportation

company  from  which  you  took  delivery  of  the  unit.

Otherwise,  all  claims  for  replacement/repair  may

be  rendered  invalid.

1.1.2 Initial operation

Please make sure the unit is provided with sufficient ventilation,

and never place the ULTRAGRAPH DIGITAL on top of an amplifier

or in the vicinity of a heater to avoid the risk of overheating.

+

Faulty  fuses  must  be  replaced  with  fuses  of

appropriate  rating  without  exception!  The  correct

value  of  the  fuses  needed  can  be  found  in  the

chapter  “SPECIFICATIONS”.

Power  is  delivered  via  the  cable  enclosed  with  the  unit.  All

requiered safety precautions have been adhered to.

+

Please  make  sure  that  the  unit  is  grounded  at  all

times.  For  your  own  protection,  you  should  never

tamper  with  the  grounding  of  the  cable  or  the  unit

itself.

1.1.3 Warranty

Please take a few minutes and send us the completely filled

out warranty card within 14 days of the date of purchase. You

may also register online at www.behringer.com. The serial number

needed for the registration is located at the top of the unit. Failure

to register your product may void future warranty claims.

1.2 The user’s manual

The user’s manual is designed to give you both an overview of

the control elements, as well as detailed information on how to

use them. In order to help you understand the links between the

controls,  we  have  arranged  them  in  groups  according  to  their

function. If you need to know more about specific issues, please

visit  our  website  at  www.behringer.com,  where  you’ll  find

additional  information  on  mixing  consoles,  effects  units  and

dynamic  processors.

Содержание Ultragrph Digital DEQ1024

Страница 1: ...User s Manual ENGLISH ULTRAGRAPH DIGITAL DEQ1024 Version 1 0 June 2003...

Страница 2: ...uding amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has tw...

Страница 3: ...noise s Integrated Pink Noise generator for perfect room and loudspeaker equalization s Digital AES EBU and S PDIF interface and selectable sample rates 44 1 48 96 kHz s Ultra high resolution 24 bit 9...

Страница 4: ...ian Meeting your expectations also meant a lot of work and night shifts But it was fun too Developing a product usually brings a lot of people together and what a great feeling it is when all who part...

Страница 5: ...ny from which you took delivery of the unit Otherwise all claims for replacement repair may be rendered invalid 1 1 2 Initial operation Please make sure the unit is provided with sufficient ventilatio...

Страница 6: ...r roughly 2 seconds Deactivating the FEEDBACK DESTROYER If you hold the RESET HOLD switch depressed for a few seconds the filter settings are reset RESET HOLD LED dies out and the FEEDBACK DESTROYER i...

Страница 7: ...vels that exceed the selected threshold value are limited and the red LIMITER LED in the METER section see lights up By reducing signal dynamics a more expressive sound is achieved The threshold range...

Страница 8: ...ches simultaneously pressed The 24 bit setting is shown by means of the 24 dB LEDs in the METER display see When the 16 bit setting is selected no METER LED lights up This way the DEQ1024 can be adjus...

Страница 9: ...ital inputs both digital outputs can be used simultaneously The POWER switch powers up your ULTRAGRAPH DIGITAL The POWER switch should always be in its Off position when you are about to connect the D...

Страница 10: ...be expensive repair costs Always keep in mind where the physical limitations of your system are Upon setting up your system as accurately as possible to the desired response curve walk around the lis...

Страница 11: ...genous sound characteristics 3 4 Special sound effects Be it in the studio on the stage or in radio plays the ULTRAGRAPH DIGITAL can become an indispensable tone tool You can for example change the so...

Страница 12: ...rse you can also connect equipment featuring un balanced outputs To this end use either mono jacks or connect ring and sleeve of the stereo jack bridge pin 1 and pin 3 when using XLR connectors Fig 4...

Страница 13: ...ers per channel automatic feedback suppression system Frequency range 20 Hz 20 kHz Bandwidth 1 10 oct Control range 48 dB in 6 dB steps MASTER Gain 9 dB to 9 dB FILTER Low Cut 20 Hz to 160 Hz 12 dB oc...

Страница 14: ...ired or replaced within 30 days of receipt of the product at BEHRINGER 2 If the product needs to be modified or adapted in order to comply with applicable technical or safety standards on a national o...

Отзывы: