Behringer Tube Ultragain T1953 Скачать руководство пользователя страница 11

11

TUBE ULTRAGAIN T1953

The LEVEL control

The  LEVEL  control  sets  the  signal  gain  at  the  input  of  the  tube  stage.  Use  this  control  to  adapt  the

TUBE ULTRAGAIN to either home recording level (-10 dBV) or professional level (+4 dBu). When this level is

too low the tube effect becomes less audible and the signal-to-noise ratio deteriorates.
To obtain the best possible signal-to-noise ratio and subsequently the best possible sound, keep an eye on the

VU level meter. If the level at the input of the tube stage is to low you will lose the tube sound and have a higher

noise floor. Use the CLIP LED above the meter to ensure that the level is not set too high. This LED may light

up briefly at signal peaks but should never light up constantly.
When using the TUBE ULTRAGAIN as microphone amplifier, set the LEVEL control to 0 dB for optimum

signal-to-noise ratio. Adjust the sensitivity with the MIC TRIM controls. If so desired you can even overdrive the

tube stages deliberately to gain a special effect. When the tubes are overdriven severely the effect resembles

the overdriving of a guitar amp. This is completely different from the subtle effect of the WARMTH control. Use

the controls with discretion, remember: less is more.

The PHASE REVERSE switch

The PHASE REVERSE switch reverses the audio signal’s phase by 180°. Usually, you won’t need this switch.

However, in some cases, it might be necessary to reverse the signal phase, for example, if a microphone cable

has been connected incorrectly (pins 2 and 3 interchanged), or if several microphones are used and specific

circumstances with regard to room acoustics are causing problems (e.g. frequency cancellations are usually

caused by phase problems). The phase reverse function will help you locate and eliminate any such problem.

The HIGH PASS switch

When you pick up acoustic signals with microphones, it is usually necessary to eliminate low-end signal

portions, such as rumble or pop noise, or other interference frequencies. Often, such frequencies have very

high amplitudes and do not only deteriorate the sound quality but can also damage the power amps or

speakers. Your TUBE ULTRAGAIN features a tunable high pass filter with a very high slope. Activate the HIGH

PASS switch and adjust the FREQUENCY control, so that any disturbing frequencies are faded out as much

as possible, with the least damage done to the actual audio signals. Press/toggle the switch several times to

make an A/B comparison.

The WARMTH control

The UTC circuitry forms an integral part of the BEHRINGER TUBE ULTRAGAIN. It provides the distinct tube

sound.  Gently  turn  the  control  clockwise  to  add  increasing  amounts  of  harmonics.  It  improves  the

transparency of other instruments, particularly those rich in upper harmonics. The WARMTH meters provide an

instant overview of the process.

3. APPLICATIONS

This section describes some typical applications of the BEHRINGER TUBE ULTRAGAIN. Starting from the

following basic settings you can use it to solve the majority of audio problems.
Please take your time to study the application examples, so as to be able to fully exploit the TUBE ULTRAGAIN

and its variety of features.
Basically, the TUBE ULTRAGAIN can be used in five areas of application:
1. Using the TUBE ULTRAGAIN as a high-quality microphone preamp.
2. Using the TUBE ULTRAGAIN to convert home recording to studio levels, and vice versa.
3. Using the TUBE ULTRAGAIN to balance unbalanced signals (DI-box).
4. Using the TUBE ULTRAGAIN to enhance the sound of the program material by adding “tube warmth”.

3.1 The TUBE ULTRAGAIN as a microphone preamp

Hook up a microphone and set the basics setting as described in chapter 2. Turn the WARMTH control fully

counterclockwise and you have a very pure and neutral mic preamp with excellent noise and distortion figures.

Turn the WARMTH control clockwise to increase the tube sound with the UTC tube stage.

3. APPLICATIONS

Downloaded from 

www.Manualslib.com

 

manuals search engine

 

Содержание Tube Ultragain T1953

Страница 1: ...TUBE ULTRAGAIN T1953 Version 1 2 December 2002 User s Manual ENGLISH Downloaded from www Manualslib com manuals search engine...

Страница 2: ...rs that produce heat Power Source The appliance should be connected to a power supply only of the type described in the operating instructions or as marked on the appliance Grounding or Polarization P...

Страница 3: ...ested musicians at the Music Fair 1997 when they saw our VINTAGER models for the first time was a lasting incentive driving our development efforts It is our philosophy to share our joy with you becau...

Страница 4: ...evel converter from 10 dBV to 4 dBu s Soft mute 48 V phantom power to avoid switch on thumps s Fully tunable and switchable 12 dB high pass filter s Switchable phase reverse to correct phase problems...

Страница 5: ...ACKGROUND 12 4 1 Audio dynamics 13 4 1 1 Noise as a physical phenomenon 13 4 1 2 What are audio dynamics 14 4 2 The tubes used in the TUBE ULTRAGAIN 15 4 3 Tube history 15 4 4 Design and functional pr...

Страница 6: ...logies making them affordable to almost anybody in audio technology With the exception of 2 12AX7 ECC83 tubes the TUBE ULTRAGAIN T1953 is based on SMD technology Surface Mounted Device These subminiat...

Страница 7: ...he connectors on the back panel Be sure that there is enough space around the unit for cooling and please do not place the TUBE ULTRAGAIN on high temperature devices such as power amplifiers etc to av...

Страница 8: ...CLIP LED warns you to reduce the gain with the MIC TRIM control so as to avoid distortion caused by overloading During normal operation the LED should not light up at all 4 The MIC TRIM control is ena...

Страница 9: ...RAGAIN in a range from 20 to 2 dB The 0 dB marker corresponds to the studio reference level of 4 dBu Set the LEVEL control so that the level meter just touches the red zone Always try to optimize the...

Страница 10: ...H PASS switch OFF LEVEL control 0 dB Tab 2 1 Basic setup of the TUBE ULTRAGAIN Reduce the volume level of the subsequent audio system to a minimum and connect a microphone to the XLR input connector o...

Страница 11: ...to eliminate low end signal portions such as rumble or pop noise or other interference frequencies Often such frequencies have very high amplitudes and do not only deteriorate the sound quality but c...

Страница 12: ...nstruments particularly those rich in upper harmonics The source material is enriched in sound volume and brilliance Enhanced depth makes it easier to locate individual instruments Vocal sounds gain i...

Страница 13: ...ource to be calculated log decimal logarithm As can be seen human hearing has a very wide dynamic range of about 130 dB which surpasses the range of a DAT or CD player with an approximate range of 96...

Страница 14: ...determined by the levels of the internal operating voltages if they are exceeded audible signal distortion is the result Although in theory the usable dynamic range sits between these two limits it is...

Страница 15: ...t developments in tube technology were reported between 1904 and 1906 It was a research task of that time to find a suitable method for receiving and rectifying high frequencies On April 12 1905 a cer...

Страница 16: ...rons When a positive dc voltage is applied to the other electrode anode the negative electrons start to wander from the cathode to the anode With reverse polarity between cathode and anode a current f...

Страница 17: ...with frequencies of 2 f 3 f etc integral multiples of the original frequency are produced These new frequencies are referred to as upper harmonics grouped as odd and even harmonics Unlike the transist...

Страница 18: ...the actual tube effect be added gradually The more you turn the Warmth control to the right the more tube sound will be added to the original signal 4 8 Studio applications In a recording studio tube...

Страница 19: ...pter thoroughly phantom power can damage the microphone if used improperly Fig 4 9 Functional diagram of phantom power supply We speak of phantom power when a microphone cable is used to carry several...

Страница 20: ...und the unit for cooling and please do not place the TUBE ULTRAGAIN on high temperature devices such as power amplifiers etc to avoid overheating 5 2 Mains connection The mains connection of the TUBE...

Страница 21: ...d operate the TUBE ULTRAGAIN During installation and operation the user must have sufficient electrical contact to earth Electro static charges might affect the operation of the TUBE ULTRAGAIN Fig 5 1...

Страница 22: ...variable 20 dB to 20 dB Warmth variable cold to warm Function switches 48 V engages the phantom power Mic Line switches from line to microphone preamp Phase reverse phase reversal 180 High Pass engag...

Страница 23: ...aced within 30 days of receipt of the product at BEHRINGER 2 If the product needs to be modified or adapted in order to comply with applicable technical or safety standards on a national or local leve...

Отзывы: