8
SUPER-X PRO CX2310
2. CONTROL ELEMENTS
2.2 Mono 3-way operation with separate subwoofer signal
First activate mono 3-way mode using the MODE switch on the rear panel (switch released). The MONO LED
on the front panel above the LOW CUT switch lights up.
Then the LEDs above the active control on the front panel light up. They show which controls are active for the mode of
operation, which you have selected. The text on the first label shows the functions of these controls.
Fig. 2.3: Active control elements on the front panel of the SUPER-X PRO in mono 3-way
operation with separate subwoofer signal
1
INPUT control.
This control adjusts the input gain from -12 to +12 dB.
2
LOW CUT switch.
This switch activates the 25 Hz high pass filter.
3
LOW/MID XOVER FREQ. control.
This control governs the crossover frequency between the low and
middle bands.
4
LOW OUTPUT control.
This controls the output level of the low band over the range -6 to +6 dB.
5
LOW PHASE INVERT switch.
This switch is used to reverse the polarity of the low output.
6
LOW MUTE switch.
This is used to mute the low band.
7
MID/HIGH XOVER FREQ. control.
This control governs the crossover frequency between the mid and
high bands.
8
MID OUTPUT control.
This is used to control the output level of the mid band over the range -6 to +6 dB.
9
MID PHASE INVERT switch.
This reverses the polarity of the mid output.
10
MID MUTE switch.
This is used to mute the mid band.
11
HIGH OUTPUT control.
This controls the output level of the high band over the range from -6 to +6 dB.
12
HIGH PHASE INVERT switch.
This reverses the polarity of the high output.
13
HIGH MUTE switch.
This is used to mute the high band.
14
XOVER FREQ. control.
This control governs the crossover frequency between the low signal and the
subwoofer signal.
15
GAIN control.
This sets the subwoofer output volume level at the SUBW.OUT output.
16
PHASE INVERT switch.
This switch is used to reverse the polarity of the subwoofer output signal.
17
MUTE switch.
This is used to mute the subwoofer output signal.