External CV Calibration

Press “Shift + STEP3” to start External CV calibration.

Complete Output CV calibration, then connect the CV out jack to the CV in jack with a 3.5mm cable.

Wait for the calibration to finish, this is indicated by all of the sequencer LEDs will light up in sequence.

Calibration is finished. Reboot the MS-1.

End of Procedure

Содержание MS-1-BK

Страница 1: ...A 2021 02 03 page 1 of 5 Confidential for internal use only Not to be reproduced User Support Bulletin Introduction The unit is carefully calibrated at the factory The performance may change over time or due to environmental changes and the following recalibration procedures can be used to bring it back to its factory settings Equipment required 1 A multimeter with 1 mv resolution 2 A 3 5 mm cable...

Страница 2: ...ered on for at least 30 minutes and that it is situated in a place where the temperature will not change drastically during calibration Calibration Procedure 1 2 4 5 6 7 8 3 No Control Set to 1 LFO RATE M 2 WAVE FORM 3 GLIDE M 4 RANGE 2 5 MAIN 6 SUB OSC 2 OCT DOWN 7 VCA GATE 8 ENVELOPE GATE No CV type Description 1 Internal CV Calibrates the internal CV 2 Output CV Tunes the CV output 3 External C...

Страница 3: ...on Output CV Calibration In this mode these buttons have new functions There are four test modes A B C D to be calibrated Their target voltage is 0V 1V 3V 5V respectively Button Name Function HOLD REST Select test mode A RESET ACCENT Select test mode B ARP SETEND Select test mode C PATTERN BANK Select test mode D SHIFT PAGE PLAY STOP REC Save Button Name Function STEP1 Select X1 about 1 mV STEP2 S...

Страница 4: ...s KYBD or STEP to adjust the CV value until it is close to target level 0V Press STEP1 STEP2 STEP3 or STEP4 to select the incremental adjustment size X1 X2 X3 or X4 Press RESET ACCENT to select test mode B Press KYBD or STEP to adjust the CV value until it is close to target level 1V Press ARP SETEND to select test mode C Press KYBD or STEP to adjust the CV value until it is close to target level ...

Страница 5: ... their respective owners Midas Klark Teknik Lab Gruppen Lake Tannoy Turbosound TC Electronic TC Helicon Behringer Bugera Oberheim Auratone and Coolaudio are trademarks or registered trademarks of Music Tribe Global Brands Ltd Music Tribe Global Brands Ltd 2021 All rights reserved External CV Calibration Press Shift STEP3 to start External CV calibration Complete Output CV calibration then connect ...

Отзывы: