Remove all unused cables from the MS-1.
Set the controls 1 to 8 to the position shown in the right hand column of this table.
Set all the other faders, knobs and switches shown in the photo.
Preparation
Make sure your MS-1 has been powered on for at least 30 minutes, and that it is situated in a place where the
temperature will not change drastically during calibration.
Calibration Procedure
1
2
4
5
6
7
8
3
No.
Control
Set to
1
LFO RATE
M
2
WAVE FORM
3
GLIDE
M
4
RANGE
2’
5
MAIN
6
SUB OSC
2 OCT DOWN
7
VCA
GATE
8
ENVELOPE
GATE
No.
CV type
Description
1
Internal CV
Calibrates the internal CV
2
Output CV
Tunes the CV output
3
External CV
Compensate oscillator offset for external CV in
Follow all steps in the order in which they are presented.