background image

3

E

This symbol, wherever it appears, alerts

you to the presence of uninsulated

dangerous voltage inside the enclosure

- voltage that may be sufficient to con-

stitute a risk of shock.

This symbol, wherever it appears, alerts

you to important operating and mainte-

nance instructions in the accompanying

literature. Read the manual.

SAFETY INSTRUCTIONS

CAUTION: To reduce the risk of electrical shock, do not remove

the cover (or back). No user serviceable parts inside;

refer servicing to qualified personnel.

WARNING: To reduce the risk of fire or electrical shock, do not

expose this appliance to rain or moisture.

DETAILED SAFETY INSTRUCTIONS:

All the safety and operation instructions should be read before the appliance is operated.

Retain Instructions:

The safety and operating instructions should be retained for future reference.

Heed Warnings:

All warnings on the appliance and in the operating instructions should be adhered to.

Follow instructions:

All operation and user instructions should be followed.

Water and Moisture:

The appliance should not be used near water (e.g. near a bathtub, washbowl, kitchen sink, laundry tub, in a wet

basement, or near a swimming pool etc.).

Ventilation:

The appliance should be situated so that its location or position does not interfere with its proper ventilation.

For example, the appliance should not be situated on a bed, sofa rug, or similar surface that may block the

ventilation openings, or placed in a built-in installation, such as a bookcase or cabinet that may impede the

flow of air through the ventilation openings.

Heat:

The appliance should be situated away from heat sources such as radiators, heat registers, stoves, or other

appliance (including amplifiers) that produce heat.

Power Source:

The appliance should be connected to a power supply only of the type described in the operating instructions

or as marked on the appliance.

Grounding or Polarization:

Precautions should be taken so that the grounding or polarization means of an appliance is not defeated.

Power-Cord Protection:

Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed

upon or against them, paying particular attention to cords and plugs, convenience receptacles and the point

where they exit from the appliance.

Cleaning:

The appliance should be cleaned only as recommended by the manufacturer.

Non-use Periods:

The power cord of the appliance should be unplugged from the outlet when left unused for a long period of time.

Object and Liquid Entry:

Care should be taken so that objects do not fall and liquids are not spilled into the enclosure through openings.

Damage Requiring Service:

The appliance should be serviced by qualified service personnel when:

- The power supply cord or the plug has been damaged; or

- Objects have fallen, or liquid has been spilled into the appliance; or

- The appliance has been exposed to rain; or

- The appliance does not appear to operate normally or exhibits a marked change in performance; or

- The appliance has been dropped, or the enclosure damaged.

Servicing:

The user should not attempt to service the appliance beyond that is described in the Operating Instructions. All

other servicing should be referred to qualified service personnel.

Содержание EURORACK MX802A

Страница 1: ...1 E User s Manual Bedienungsanleitung D E EURORACK MX802A Version 1 0 January 1999 www behringer de...

Страница 2: ...product EURORACK MX802A Type designation and article No if applicable to which this declaration refers is in accordance with the following standards or stan dardized documents x EN 60065 x EN 61000 3...

Страница 3: ...f air through the ventilation openings Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliance including amplifiers that produce heat Po...

Страница 4: ...witchable low Cut Filter on all Mono Channels s 2 Aux Sends per channel for external effects and monitoring s Separate Main Mix Control Room and Headphone Outputs s 2 Track Inputs assignable to Main M...

Страница 5: ...t suggestions for new products you ve greatly contributed to shaping our company and making it successful In return we guarantee you uncompromising quality manufactured under ISO9000 certified managem...

Страница 6: ...9 3 3 Aux Sends 9 3 4 Volume control and panning balancing 9 4 MAIN SECTION 9 4 1 Aux Sends 9 4 2 StereoAux Returns 10 4 3 Metering 10 4 4 2 Track Input Main Mix Output 10 4 5 Monitoring 10 5 SETTING...

Страница 7: ...tant power Channel Pan potentiometer Aux Send There are two Aux Send busses on the MX802A Aux 1 is pre fader Aux 2 is post fader the channel s volume control Stereo Line Inputs There are two line leve...

Страница 8: ...in section 5 SETTING UP However if the PEAK LED does not light the input gain cannot be too high If a reasonable input level is selected auditioning a single signal should result in a reading of arou...

Страница 9: ...except that the EQ is stereo of course A stereo equalizer is generally preferable to using two mono equalizers when EQ ing a stereo signal as often discrepancies between left and right settings can oc...

Страница 10: ...pair of accurate 12 segment bargraph peak meters Two further LEDs indicate Power on and 48 V DC Phantom Power present The Main Mix bargraph meters should average around 0 dB during loud passages If t...

Страница 11: ...hantom Power switched on Never use unbalanced mic cables with the Phantom Power switched on ever Shorting the 48 V to earth can cause serious damage 2 Stereo Channels accept any line level signals Any...

Страница 12: ...vel to the limit and fully exploit 16 bit digital s 96 dB dynamic range for example you ll have to do some calibrating How to do it Well you could run a tone at 0 dB from the mixer and use that as you...

Страница 13: ...got the right ones Unbalanced equipment may be connected to balanced inputs outputs Either use mono 1 4 jacks or connect ring and sleeve of TRS jacks Fig 6 1 Headphone connection 1 2 3 2 1 3 Pin 1 Ca...

Страница 14: ...to other devices in a balanced configuration to allow for maximum interference immunity Unbalanced use of mono 1 4 jack plugs Ring Balanced use of stereo 1 4 jack plugs Balanced use with XLR connector...

Страница 15: ...at 4 dBu 1 kHz Bandwidth 80 kHz Equalization Hi Shelving 12 kHz 15 dB Mid Range 2 5 kHz 15 dB Lo Shelving 80 Hz 15 dB Main Mix section Max Output 22 dBu balanced Aux Send Max Out 22 dBu unbalanced Con...

Страница 16: ...16 16 7 APPENDIX 7 2 Front back views...

Страница 17: ...17 E 17 7 APPENDIX 7 3 Block diagram...

Страница 18: ...t complete and return the enclosed warranty card signed stamped by retail dealer within 14 days of the date of purchase to BEHRINGER INTERNATIONAL address see 3 Failure to return the card in due time...

Отзывы: