![BEHLMAN P1351 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/behlman/p1351/p1351_users-manual-and-technical-reference-manual_2721411008.webp)
2
SECTION1
P1351 AC POWER SUPPLY INTRODUCTION
P1351 AC POWER SUPPLY SPECIFICATIONS
INPUT REQUIREMENTS:
120 VAC +/- 10% 47-440 Hz
OUTPUT POWER:
1350 VAC MAX. ( with input @ 120 VAC)
LOAD POWER FACTOR:
Zero to Unity with no derating.
OUTPUT VOLTAGE:
0 -135VAC @ 10 AMPS AND 0-270VAC @ 5 AMPS
OUTPUT FREQUENCY:
Continuously adjustable from 45 to 500 Hz.
OUTPUT REGULATION:
Less than 1% of full scale from no load to full load
SETTLING TIME:
Approximately 200mSec to 1%. 10-90% (linear load)
LINE REGULATION:
+/- 0.1% for +/- 10% line change @ 115V 10A/230 5A
OUTPUT DISTORTION:
1% Typical @ 115 V 50Hz into pure resistive load.
.
OUTPUT NOISE :
2.5 V peak to peak typ.( on low range into 10 ohms.)
FRONT PANEL METERS
:
VOLTMETER RESOLUTION:
1 Volt
ACCURACY:
2% of reading + ( +/- 1digit ) RMS responding
AMMETER RESOLUTION:
.01 Amp
ACCURACY:
2% of r ( +/- .5 % of range) RMS responding.
FREQUENCY RESOLUTION
1 Hertz
ACCURACY
2% S ( +/- 1 Hertz )
PROTECTIVE CIRCUITS:
SHORT CIRCUIT
Inverter latches off in response to output short. Response time less than
20usec.
CONSTANT CURRENT
Responds to long term overloads by reducing output voltage. Set @
approximately 110% of rated current for range in use. 250mSec approximate
response time.
MISCELLANEOUS:
PHYSICAL
Steel chassis, 17" W x 19" D x 3.5" H. 45 lbs.
TEMPERATURE RANGE
0 - 50 Degrees Celsius (operating) -10C to +65C (storage)