5-1-4
1.4
AC POWER SUPPLY SYNTAX
Setup Command:
FNC ACS :CHO SET VOLT <value>
[ SET FREQ <value>]
[ SRX VOLT <value>]
[ SRN VOLT <value>]
[ SRX FREQ <value>]
[ SRN FREQ <value>]
[SET VLT(0,1)] <cr><lf>
Table 1-1
CIIL SOFTWARE COMMANDS
CIIL COMMANDS
EXPLANATION
SET VOLT <value>
Sets output voltage to given value,in volts rms. The following values are
permitted:
0 < value < 135, or 270, dependent on range selected and type of unit.
If set volt (value) not received, then use SRN VOLT (value), or SRX
VOLT (value). If none of these 3 are sent then generate error message.
SET FREQ <value>
Optional. Sets frequency of output voltage to given value, in Hz. The
following values are permitted:
45 < value < 500.
Default is 45 Hz only if SET FREQ, SRN FREQ, or SRX FREQ are not
received. Otherwise the values shall be used in the order stated.
SRX VOLT <value>
Optional. Sets maximum limit for SET VOLT command. If SET VOLT
value is greater than SRX VOLT value in a command string, an error
message is generated and the setup command ignored. The following
values are permitted:
0 < value < 135, or 270, dependent on range selected and type of unit.
If a value for SRX VOLT is not specified, the required maximum value
for SET VOLT default to 135, or 270, dependant on range selected and
type of unit.