6
SECTION 3
P1350 AC POWER SUPPLY OPERATING INSTRUCTIONS
Before operating this equipment the user should become familiar with the controls and indicators provided.
These are summarized in the table 3-1. Refer to figure 3-1 (previous page) for locations.
ITEM#
DESIGNATION
FUNCTION / DESCRIPTION
1
POWER
switch
Controls input line power.
2
FREQUENCY
switch
Selects one of three output frequencies. 50,60 or 400Hz
3
FAULT
LED
Indicates unit disabled due to overload ( short circuit ).
4
VOLTS
display
LED readout of the units output voltage .
5
VOLTS
adjust control
Multi-turn control provides continuous adjustment of the unit's
output voltage. See item 4.
6
RANGE
switch
Selects output voltage range of 0-135V or 0 -270V. See
operating instructions for more information.
7
Output Receptacle
“Shuko” type receptacle use to connect directly to load or for
accepting various output adaptors. Several types are
available from Behlman. See chart in this manual.
8
Input power Receptacle
Mates with IEC-20 type line plug. Note: a NEMA 15P to IEC-
20 molded line cord is supplied with unit. See operating
considerations in this manual.
9
Line fuse Receptacle
Screw type fuse holder for line fuse. 25A @ 132V Slow.
CAUTION ! For continued protection against fire, replace
fuse with same type and rating only.
See section 3 of this
manual for more information
10
Fan exhaust
Heated air is exhausted at the rear of the unit. A minimum
clearance of 4 inches is required for proper cooling.
11
REMOTE
option
This area reserved for optional DC remote control board.
And/or rear output terminal block.