Sorting out a single wire in a bundle of cables and trace lines
in overhead installations
• Switch on the instrument via the switch on/off and sensitivity potentiometer
(5).
• Set selection switch between Fuse and Cable to "Cable” (4).
• Plug the transmitter into socket of respective current circuit.
• Set sensitivity via sensitivity potentiometer (5) to the highest sensitivity.
• Now approach the plugged-in transmitter with the sensor (1) and try to re-
ceive a signal. A signal received is indicated by the symbol "H" (6) on the dis-
play as well as the blinking of the LED (2). At the same time an acoustic si-
gnal is audible depending on the intensity of the signal.
• Now try to locate the signal at the bundle of cables or overhead installation.
If a signal is received, reduce the sensitivity level via the potentiometer (5)
until the minimum reception of the signal is achieved. If required, reset the
sensitivity level via the potentiometer (5), in order to retrieve the signal (see
drawing below).
Depending on local conditions, the tracing distance amounts to approx. 0...40 cm.
6
PTDB20250000-00.qxd 30.11.2005 16:12 Uhr Seite 6