8.4 Fuse replacementl
Prior to fuse replacement,
ensure that multimeter is dis-
connected from external vol-
tage supply and the other
connected instruments (such
as UUT, control instruments,
etc.).
Exclusively use fuses of volta-
ge and current values in com-
pliance with the technical data
section.
Using auxiliary fuses, in particular
short-circuiting fuse holders is
prohibited and can cause instru-
ment destruction or serious bodily
injury of operator.
c
Switch of the instrument.
c
Loosen the screws on the
instrument rear.
c
Lift the case cover.
c
Remove the defect fuse.
c
Insert new fuse.
c
Replace the case cover and
retighten the screws
FS1: 1A / 240V, IR 6kA (Bussmann
TDC180-1A or other with compari-
son value) UNITEST Order No.:
ES1000MAF001
FS2: 13A / 240V, IR 6kA (Bussmann
TDC180-13A or other with compa-
rison value) UNITEST Order No.:
ES13000MAF
Fuse replacement