Cable Length Measurement (reference ranges)
Conductor cross section ....................................................0.05...500mm2
Ranges................................................................................84 cross sections / cable types
Measurement ranges / resolution........................................0.1 m...1999.9m / 0.1m
............................................................................................1 m...19999m / 1m
Measurement range selection ............................................automatic
Accuracy ............................................................................±(2% rdg. + 5 digits)
Determination of Conductor Cross Section
Measurement range / resolution..........................................0.1...100mm2 / 0.1mm2
............................................................................................1...500mm2 / 1mm2
Measurement range selection ............................................automatic
Accuracy ............................................................................±(2% rdg. + 5 digits)
Resistance Measurement
Measurement range / resolution..........................................0.5...200 Ohm / 0.01 Ohm
............................................................................................0.5...2000 Ohm / 0.1 Ohm
Measurement range selection ............................................automatic
Accuracy ............................................................................±(2% rdg. + 5 digits)
Continuity Test
Resistance range ................................................................0...10 Ohm
Display ................................................................................acoustic
Measurement range selection ............................................automatic
Test current ........................................................................max. 10mA
12 month Warranty
UNITEST instruments are subject to strict quality control. However, should the instrument function improp-
erly during daily use, your are protected by our 12 months warranty (valid only with invoice).
We will repair free of charge any defects in workmanship or material, provided the instrument is returned un-
opened and untampered with, i.e. with undamaged warranty label.
Any damage due to dropping or incorrect handling are not covered by the warranty.
If the instrument shows failure following expiration of warranty, our service department can offer you a quick
and economical repair.
32
Содержание Unitest 2005
Страница 17: ...UNITEST Cable Length Meter 3000 Instruction Manual Cat No 2005 ...
Страница 33: ...UNITEST Câblemètre 3000 Mode d emploi Réf 2005 ...
Страница 49: ...UNITEST Medidor de cables 3000 Manual de instrucciones no de ref art 2005 ...
Страница 66: ...66 ...
Страница 68: ...68 Änderungen vorbehalten 03 2001 PTDB2005 00 Reg No 3335 ...