6
GAS CYLINDER SAFETY INFORMATION
SAFETY INFORMATION
Gas cylinders must be stored outdoors, out of reach of children
and must not be stored in a building, garage or any other
enclosed area.
• This appliance is designed to be used with a gas cylinder
not exceeding 9KG (20lbs) capacity.
• The Gas cylinder must be constructed and marked in
accordance with specifications for LP Gas Cylinders.
• Ensure gas cylinder is within the expiration date, it is not
advised to use or attempt to refill a gas cylinder that is
outside of it’s expiration date.
• The gas cylinder supply valve must be turned off when the
appliance is not in use.
• The gas cylinder used must incorporate a safety collar to
protect the valve assembly.
• The gas cylinder must always be kept and used in the
upright position.
TIPS & INFORMATION
IMPORTANT
When disconnecting and removing the gas cylinder for the
purpose of refilling, always observe the following procedure:
• Ensure that all gas control valves on the appliance and the
gas cylinder are turned off before disconnecting the gas line
from the cylinder.
• Do not smoke or use a naked flame near the appliance or
gas cylinder while disconnecting the gas line between the
appliance and gas cylinder.
• Remove the gas cylinder from the enclosure before
disconnecting the gas line from the appliance.
• Tighten all connections before placing the gas cylinder back
in its enclosure.
The Gas Leak Testing Procedure should be conducted every time
the gas cylinder is refilled and reconnected to the appliance –
before using the appliance.
Regulator Connection
1. Check that all control knobs are in the ‘Off’ position.
2. Make sure the cylinder valve is off by turning the valve
knob all the way clockwise.
3. Remove the protective cap from the cylinder if present.
4. Make connection as described in figures 1 and 2.
5. Leak-test the connection with a soapy water solution. (See
Gas Leak Testing Procedure).
Hose and regulator replacement must be a genuine part
specified for this appliance and is obtainable from your nearest
BeefEater stockist.
FIG 1
Standard POL regulator
FIG 2
Quick connect regulator