21
NATURAL GAS CONVERSION
Natural gas installation
NOTE: Conversion of this unit to natural gas must be carried out
by a qualified licenced person and a Certificate of Compliance
must be issued to the owner on completion of the installation
conversion.
Converting to natural gas (to the installer)
This barbecue is supplied set up for Universal LPG and is
labelled accordingly. A natural gas conversion kit is available as
an accessory by contacting Electrolux customer service.
1 x Natural gas hose and regulator assembly with quick
connect bayonet fitting.
1 x bag containing:
5 x 45° valve with 1.90mm injectors
1 x 90° valve with 1.80mm injector
1 x Natural gas label
Procedure
1. Remove side tables to gain access to control panel screws.
2. Remove knobs and for each bezel remove 2 screws retaining
the bezel to the valve.
bezel screws
control panel
screws
3. At each end of the control panel, remove 3 screws retaining
the control panel.
4. Remove control panel to access the valves
5. Remove each valve and replace with valve provided in the
natural gas conversion kit, note the injector size, as shown
on page 14.
6. Remove the hose and regulator assembly, and replace the hose
and regulator appropriate for the intended gas supply.
7. Turn on gas & check for leaks at every connection (use soap
solution to identify leaks.)
8. Replace the control panel, bezels and the knobs.
9. Check and adjust if necessary the supply pressure is
1.13kPa.
10. The operation of the regulator can be confirmed by
connecting a manometer to the test point located on the
side of the regulator body. With three burners operating at
maximum the outlet pressure should measure 1.0kPa.
Side burner conversion