•Under keyboard operating mode, as F-12=1 or 2 and F-19=6, the rotary direction is
controlled by multi-functions contact 3, which means the inverter can be started in
reverse direction under the mode of keyboard operation.
•Under keyboard operating mode, as F-12=1 or 2 and F-19=7, multi-function contact 2
and 3 “ON” simultaneously which would activate the function of “Rapid linear
deceleration function (F-07).
9.2
Parameter explanation
Standard parameter group
•F-01 max output frequency
Maximum frequency limitation
(Speed, refer to F-10)
•F-02 min output frequency
Minimum frequency limitation
(Speed, refer to F-10)
•F-03 linear Accel time(S).
The required time accelerate from 0 to max speed.
•F-04 linear Decel time(S).
The required time decelerate from max speed to 0
•F-05 stop mode select
0: Decelerate and stop according to parameter F-04;
2: Decelerate and stop according to parameter F-07;
1: Input “Stop” instruction, motor coast to stop (inertially).