7.5
Parameters resume default (Parameters reset)
•When inverter stop and appear “Stop” on LCD, simultaneity press
,
and “Enter” Key
0
1 second
•LCD appears P-SET, which means all parameters have resumed to
default (ex-work value).
•Press “Enter” Key
0
again, LCD appears “Stop”.
•Parameter F-37 would restore to 10, but F-39 and F-40 not change.
7.6
The saving condition after parameter modification
•As F-38=0 (Default), all parameters could be modified, they would be
saved in EEPROM when AC main power is cut off.
•As F-38=1, all parameters could also be modified, but they would not
be saved in EEPROM when AC main power is cut off.
•As F-38=2, all parameters couldn’t be modified, read only.
Notice
To prevent other persons modify parameters causally, please select any
number between 0 and 9999 for parameters F-37 (enter into “Extended
menu access” password).
•Under status of “Extended menu access”
(
expect F-00
)
,LCD would
return to initial status if without any operation within 20 seconds.
•when set as F-00, LCD would return to initial status if without any
operation over 60 seconds.