Mounting and demounting

The ZB8610 fan cartridge is snapped onto a 48-mm wide terminal group of Beckhoff standard or high-
density (HD) terminals using the "8-channel/16-channel fan cartridge holder" supplied as an accessory.

Fig. 3: Fan cartridge holder, 8-channel

Fig. 4: Fan cartridge holder, 16-channel

The width of the individual terminals may be 12 mm (single width) or 24 mm (double width) or a combination
of both.
The mounting of the ZB8610 is described below by way of an example.

WARNING

Risk of injury through electric shock and damage to the device!

Bring the Bus Terminals system into a safe, de-energized state before starting mounting,
disassembly or wiring of the Bus Terminals.

Содержание ZB8610

Страница 1: ...Documentation ZB8610 Fan cartridge for EtherCAT and Bus Terminals 1 5 2017 08 07 Version Date...

Страница 2: ......

Страница 3: ...n 5 1 2 Safety instructions 6 1 3 Documentation issue status 7 2 Product overview 8 2 1 Introduction 8 2 2 Technical data 10 2 3 Mounting and demounting 11 2 4 LED display and connection 17 2 5 Basic...

Страница 4: ...Table of contents ZB8610 4 Version 1 5...

Страница 5: ...data diagrams and descriptions in this documentation Trademarks Beckhoff TwinCAT EtherCAT Safety over EtherCAT TwinSAFE XFC and XTS are registered trademarks of and licensed by Beckhoff Automation Gm...

Страница 6: ...liar with the applicable national standards Description of symbols In this documentation the following symbols are used with an accompanying safety instruction or note The safety instructions must be...

Страница 7: ...omment 1 6 Update chapter Commissioning 1 5 Update chapter Technical Data 1 4 Update chapter Technical Data 1 3 Update chapter Basic Function Principles and Commissioning 1 2 Addenda 1 1 Addenda 1 0 A...

Страница 8: ...om the housing It extends the thermal operating range of EtherCAT Terminals ELxxxx and Bus Terminals KLxxxx and offers a wide range of new application options The cartridge is installed on the undersi...

Страница 9: ...Product overview ZB8610 9 Version 1 5 Fig 2 Components ZB8610...

Страница 10: ...Diagnostics max output current fan fault 15 mA Life span MTBF typ 280 000 h 20 C Special features increased performance and extended temperature range for various terminals Dimensions W x H x D 47 mm...

Страница 11: ...sory Fig 3 Fan cartridge holder 8 channel Fig 4 Fan cartridge holder 16 channel The width of the individual terminals may be 12 mm single width or 24 mm double width or a combination of both The mount...

Страница 12: ...mm and snap the holder on the left in the lower ventilation cut outs of the first terminal to be ventilated as shown in fig Engaging the holder for the fan cartridge Fig 5 Engaging the holder for the...

Страница 13: ...Push the fan cartridge onto the holder as shown in fig Attaching the fan cartridge The holding tab and the recess see fig Push fan cartridge with recess over holding tab on the fan cartridge fit each...

Страница 14: ...an cartridge with recess over holding tab 3 Make sure that the latching tab is pushed into the groove until a click noise is heard as in fig Push latching tab into groove The fan cartridge is now corr...

Страница 15: ...15 Version 1 5 Fig 11 Correctly attached fan cartridge front view Fig 12 Correctly attached fan cartridge side view Removal 1 To dismantle pull the fan cartridge off the terminal group in the directi...

Страница 16: ...er until the holder releases Fig 14 Remove the holder using a screwdriver Note Clearance of the fan cartridge module When installing terminals with mounted fan cartridge module ensure that an adequate...

Страница 17: ...nnection Designation Meaning 24 V 24 V power supply 0 V 0 V power supply Mode Input speed regulation via external voltage 0 V revolution temperature controlled 1 Hz approx 2700 U min 2 Hz approx 3150...

Страница 18: ...Connect the ZB8610 fan cartridge according to the instructions in the section LED display and connection 17 The fan can be operated in three different modes 1 Demand based control via an integrated te...

Страница 19: ...UL certified without restrictions UL certification according to UL508 with limited power consumption The current consumed by the device is limited to a max possible current consumption of 4 A Devices...

Страница 20: ...nents there Beckhoff Headquarters Beckhoff Automation GmbH Co KG Huelshorstweg 20 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 e mail info beckhoff com Beckhoff Support Support offer...

Страница 21: ...tly engaged holder front view 12 Fig 7 Correctly engaged holder side view 13 Fig 8 Attaching the fan cartridge 13 Fig 9 Push fan cartridge with recess over holding tab 14 Fig 10 Push latching tab into...

Отзывы: