Technical data, mounting, wiring
PS3011-2440-0000
26
Version: 1.0
3.16
Environment
Environment
Operating temperature
1)
-25°C to +70°C
Reduction of the output power according to
Fig.
Output current over ambient temperature
Storage temperature
-40°C to +85°C
For storage and transport
Output load reduction
(derating)
24 W/°C
+60°C to +70°C
Humidity
2)
5 to 95% r.h.
According to IEC 60068-2-30
Oscillation, sinusoidal
2-17.8 Hz: ±1.6 mm;
17.8-500 Hz: 1 g
2 hours/axis
According to IEC 60068-2-6,
Higher values are permissible when the wall-
mounting bracket (ZS5301-0002) is used
Impact
15 g 6 ms, 10 g 11 ms
3 impacts/direction, 18 impacts
in total
According to IEC 60068-2-27,
Higher values are permissible when the wall-
mounting bracket (ZS5301-0002) is used
Installation altitude
0 to 2000 m
Without restrictions
2000 - 6000 m
Reduce the output power or the ambient
temperature, see Fig.
Output current over
installation altitude
IEC 62103, EN 50178, overvoltage category
II
Derating, installation altitude 60 W/1000 m or 5°C/1000 m
> 2000 m, see Fig.
Output current over
installation altitude
Overvoltage category
III
According to IEC 62103, 50178, installation
altitudes up to 2000 m
II
Installation altitudes between 2000 m and
6000 m
Degree of pollution
2
According to IEC 62103, EN 50178, non-
conductive
LABS-free
The device does not release any silicones or other paint-wetting impairment
substances and is suitable for use in paint shops.
1)
The working temperature is identical to the room temperature or the ambient temperature and is defined as
the air temperature 2 cm below the device.
2)
Do not energize when condensation is present!
Fig. 17: Output current over ambient temperature; output current over installation altitude
Содержание PS3011-2440-0000