background image

Technical data, mounting, wiring

PS2001-4810-0000

23

Version: 1.0

3.13

EMC

The EMC behavior of the device is designed for applications in industrial environments as well as residential,
commercial or small business environments.

The device was tested according to EN 61000-6-1, EN 61000-6-2, EN 61000-6-3 and EN 61000-6-4.

Without additional measures to reduce emissions at the output (e.g. by using a filter), the device is not
suitable for supplying a local DC power network in residential, commercial or small business environments.
There are no restrictions for local DC power networks in industrial environments.

EMC interference immunity

Strong transients

VDE 0160 Over the entire load

range

750V, 0.3ms

EMC interference emission

Cable-related interference emission, input
lines

EN 55011, EN 55022, FCC Part 15,
CISPR 11, CISPR 22

Class B

Interference emission

EN 55011, EN 55022

Class B

Harmonic input current

EN 61000-3-2

Class A requirements met
Class C met between 4A and 12A load

Voltage fluctuations, flicker

EN 61000-3-3

Requirements met 

1)

This device complies with FCC Part 15.

Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must be
able to deal with any interference received, including interference that may cause undesired operation.

1)

 Tested with constant current loads, non-pulsating

Switching frequencies

PFC converter

100kHz

fixed frequency

Main converter

80kHz to 140kHz

Output load dependent

Auxiliary converter

60kHz

fixed frequency

Содержание PS2001-4810-0000

Страница 1: ...Documentation EN PS2001 4810 0000 Power supply 48 V DC 10 A 1 phase 2020 10 08 Version 1 0...

Страница 2: ......

Страница 3: ...20 3 11 Functional wiring diagram 21 3 12 Front side and operating elements 22 3 13 EMC 23 3 14 Environment 24 3 15 Protective functions 25 3 16 Safety features 25 3 17 Dielectric strength 26 3 18 Dec...

Страница 4: ...Table of contents PS2001 4810 0000 4 Version 1 0...

Страница 5: ...with a continuous maximum output power of 120 and can precisely trigger fuses with a short peak current The power supply unit is part of the PS2000 family and has a width of 48 mm A DC OK LED and a po...

Страница 6: ...are registered trademarks of and licensed by Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the...

Страница 7: ...device is designed for installation in a housing and is intended for general professional use for example in industrial control systems or office communication and measuring equipment Do not use this...

Страница 8: ...r Do not touch the device when it is switched on or immediately after it has been switched off Hot sur faces can cause burns WARNING Explosion hazard warning Do not use with DC input voltages Do not u...

Страница 9: ...the PE terminal must not exceed 300Vac continuously The input can also be powered from batteries or similar DC power sources The voltage between the input terminal and the PE terminal must not exceed...

Страница 10: ...ith tolerances e g AC 230 V 10 The calculated total range then indicates the working range of the device Example DC 12 V refers to a 12 V battery regardless of whether it is fully charged 13 7 Vdc or...

Страница 11: ...10A see Fig Input current over output current power factor over output current Power factor Typ 0 996 0 996 0 980 At 48V 10A see Fig Input current over output current power factor over output current...

Страница 12: ...Technical data mounting wiring PS2001 4810 0000 12 Version 1 0 Fig 2 Input current over output current power factor over output current...

Страница 13: ...ng to IEC 60664 1 Turn on voltage Typ 80 Vdc static Shut down voltage Typ 70 Vdc static Instructions for DC operation The device is suitable for supply from a DC input voltage Use a battery or a compa...

Страница 14: ...tched on The charge current of the interference suppression capacitors during the first few microseconds after switching on is not taken into account AC 100V AC 120V AC 230V Input inrush current Max 1...

Страница 15: ...nd 70 C ambient temperature Linear derating between 45 C and 70 C Safety switch off current Typ 30A Up to 12ms once every five seconds see Fig Dynamic output current capacity typ The fuse switch off c...

Страница 16: ...fter a loss of input power The Hold up time depends on the output load At no load the Hold up time can be up to several seconds The green DC OK lamp also lights up during this time AC 100V AC 120V AC...

Страница 17: ...voltage The contact opens when the output voltage drops more than 10 below the set output voltage Short drops are extended to a signal length of 100ms Drops that are shorter than 1ms are ignored Switc...

Страница 18: ...W 10 6W At 48V 5A Typ 28 5W 25 1W 18 4W At 48V 10A Typ 35 4W 31 0W 22 7W At 48V 12A Extra Power The average efficiency is based on assumptions for a typical application with the power supply unit oper...

Страница 19: ...MTBF MTBF stands for Mean Time Between Failure which is calculated from the statistical failure rate of the components and indicates the reliability of a device It is a statistical representation of t...

Страница 20: ...ions Use suitable copper cables that are designed for at least the following operating temperatures 60 C for ambient temperatures up to 45 C 75 C for ambient temperatures up to 60 C and 90 C for ambie...

Страница 21: ...Technical data mounting wiring PS2001 4810 0000 21 Version 1 0 3 11 Functional wiring diagram Fig 12 Functional wiring diagram...

Страница 22: ...V DC OK LED Designation D Description LED green Lights when the output voltage has reached 90 of the set output voltage DC OK relay contact Designation E Description Push in terminals 13 14 Monitors t...

Страница 23: ...0160 Over the entire load range 750V 0 3ms EMC interference emission Cable related interference emission input lines EN 55011 EN 55022 FCC Part 15 CISPR 11 CISPR 22 Class B Interference emission EN 55...

Страница 24: ...altitudes up to 2000m II According to IEC 60664 1 installation altitudes above 2000m Degree of pollution 2 According to IEC 62477 1 non conductive Oscillation sinusoidal 2 2 17 8Hz 1 6mm 17 8 500Hz 2...

Страница 25: ...ction against input transients MOV metal oxide varis tor For further information see EMC chapter 23 Input fuse Included Non replaceable slow blow fuse with high load capacity 3 16 Safety features Safe...

Страница 26: ...current to the value shown in the table below We recommend connecting either the positive pole the negative pole or another part of the output circuit to the protective conductor system This avoids s...

Страница 27: ...on of conformity UL Certificate UL 61010 1 2 201 Applicable for US and Canada UL Certificate Class I Division 2 Groups A B C D locations and for use in Group II Category 3 Zone 2 environments Applicab...

Страница 28: ...ulate the total installation depth required Weight 830 g DIN rail Use 35 mm DIN rails according to EN 60715 or EN 50022 with a height of 7 5 or 15mm Housing material Housing Aluminum alloy Cover Galva...

Страница 29: ...citive load The peak current capability also ensures safe operation of downstream circuit breakers of load circuits The load circuits are often individually fused with circuit breakers or fuses In the...

Страница 30: ...t Control of DC OK relay Please note The DC OK relay is activated if the voltage drops by more than 10 for more than 1ms Peak current voltage drops Typically from 48V to 36V At 20A for 50ms ohmic load...

Страница 31: ...s with high reserve current and large output capacitors In addition the impedance of the faulty branch must be sufficiently small for the current to actually flow The strongest power supply is of no u...

Страница 32: ...ies connection Power supplies of the same type can be connected in series to increase the output voltages As many devices can be connected in series as necessary as long as the sum of the output volta...

Страница 33: ...up and shut down the input power turn off for at least five seconds if the output was overloaded or short circuited and the required output current is higher than the current of a device Restrictions...

Страница 34: ...heat generating objects in the box The load is placed outside the enclosure The temperature sensor inside the enclosure is placed at the center of the right side of the power supply at a distance of...

Страница 35: ...permissible output currents for altitudes up to 2000m Fig 24 Mounting position A standard mounting position Fig 25 Mounting position B upside down Fig 26 Mounting position C table mounting Fig 27 Mou...

Страница 36: ...devices to a wall or panel without using a DIN rail The bracket can be mounted without loosening the DIN rail brackets For more information please refer to the ZS5301 0003 documentation Fig 29 Isomet...

Страница 37: ...Appendix PS2001 4810 0000 37 Version 1 0 5 2 Documentation issue status Version Comment 1 0 First public issue 0 2 Complements corrections 0 1 Preliminary documentation for PS2001 4810 0000...

Страница 38: ...khoff components there Beckhoff Support Support offers you comprehensive technical assistance helping you not only with the application of individual Beckhoff products but also with other wide ranging...

Страница 39: ......

Страница 40: ...Beckhoff Automation GmbH Co KG H lshorstweg 20 33415 Verl Germany Phone 49 5246 9630 info beckhoff com www beckhoff com More Information www beckhoff com ps2001 4810 0000...

Отзывы: