background image

Содержание KL3224

Страница 1: ...Documentation EN KL3224 Four channel analog input terminal for PT1000 Ni1000 2021 07 07 Version 2 0 0...

Страница 2: ......

Страница 3: ...nection system 18 3 3 2 Wiring 19 3 3 3 Shielding 21 3 3 4 Connection 21 4 Configuration Software KS2000 22 4 1 KS2000 Introduction 22 5 Access from the user program 24 5 1 Terminal configuration 24 5...

Страница 4: ...Table of contents KL3224 4 Version 2 0 0...

Страница 5: ...oducts that have already been supplied may be made on the basis of the data diagrams and descriptions in this documentation Trademarks Beckhoff TwinCAT TwinCAT BSD TC BSD EtherCAT EtherCAT G EtherCAT...

Страница 6: ...ained specialists in control automation and drive engineering who are familiar with the applicable national standards Description of instructions In this documentation the following instructions are u...

Страница 7: ...rsions Documentation Version KL3224 0000 Firmware Hardware 2 0 0 1B 06 1 0 1B 03 The firmware and hardware versions delivery state of the terminal can be found in the serial number printed on the side...

Страница 8: ...product it can be found in the following places on the packaging unit directly on the product if space suffices on the packaging unit and the product The BIC is machine readable and contains informat...

Страница 9: ...a identifiers are used by Beckhoff and serve internal processes Structure of the BIC Example of composite information from item 1 to 4 and 6 The data identifiers are marked in red for better display B...

Страница 10: ...isplayed as follows 1 10 C 1 digit 0 1 C In addition to this a broken wire or short circuit is reported to the Bus Coupler or to the controller and indicated by the ERROR LED NI1000 and PT1000 element...

Страница 11: ...0 C 55 C Permissible ambient temperature during storage 25 C 85 C Permissible relative humidity 95 no condensation Vibration shock resistance conforms to EN 60068 2 6 EN 60068 2 27 EMC immunity emiss...

Страница 12: ...00 for PT100 R 18 Bits 0 and 6 underrange and error bits in the status byte are set The smallest negative number is displayed 0x8001 corresponds to 32767 For overrange or underrange the red error LED...

Страница 13: ...ensor resistance value Y_T measured temperature in 1 16 C Y_THS Temperature after manufacturer scaling 1 10 C Y_TAS Temperature after user scaling Y_AUS Process data to PLC X_R X_RTD X_RL Y_R A_a X_R...

Страница 14: ...ure you are electrostatically discharged and avoid touching the contacts of the device directly Avoid contact with highly insulating materials synthetic fibers plastic film etc Surroundings working pl...

Страница 15: ...coupler Join the compo nents with tongue and groove and push the terminals against the mounting rail until the lock clicks onto the mounting rail If the terminals are clipped onto the mounting rail fi...

Страница 16: ...ents The six spring contacts of the K Bus E Bus deal with the transfer of the data and the supply of the Bus Terminal electronics The power contacts deal with the supply for the field electronics and...

Страница 17: ...sting or to damage on the terminal e g disruptive discharge to the PE line during insulation testing of a consumer with a nominal voltage of 230 V For insulation testing disconnect the PE supply line...

Страница 18: ...nsity Standard wiring ELxxxx KLxxxx Fig 8 Standard wiring The terminals of ELxxxx and KLxxxx series have been tried and tested for years They feature integrated screwless spring force technology for f...

Страница 19: ...design as the packaging density is twice as large as that of the standard 12 mm bus terminals Massive conductors and conductors with a wire end sleeve can be inserted directly into the spring loaded...

Страница 20: ...e wire size width Terminal housing ELxxxx KLxxxx ESxxxx KSxxxx Wire size width single core wires 0 08 2 5 mm2 0 08 2 5 mm2 Wire size width fine wire conductors 0 08 2 5 mm2 0 08 2 5 mm2 Wire size widt...

Страница 21: ...Connection Terminal point No Comment R1 1 Input R1 R1 2 Input R1 R3 3 Input R3 R3 4 Input R3 R2 5 Input R2 R2 6 Input R2 R4 7 Input R4 R4 8 Input R4 KL3224 LED Displays LED Color Description Error re...

Страница 22: ...s Box Modules can be prepared before the commissioning phase Later on this configuration can be transferred to the terminal station in the commissioning phase by means of a download For documentation...

Страница 23: ...es directly online The same high level dialogs and register access are available for this purpose as in the configuration phase The KS2000 offers access to the process images of the bus couplers and F...

Страница 24: ...trol and status byte also has to be mapped BK2000 Lightbus Coupler In the BK2000 Lightbus coupler the control and status byte is mapped in addition to the data bytes This is always located in the low...

Страница 25: ...tly of the fieldbus system with the KS2000 configura tion software via the serial configuration interface in the Bus Coupler 5 2 Mapping in the Bus Coupler As already described in the Terminal Configu...

Страница 26: ...omplete evaluation yes Motorola format no Word alignment yes 0 Res Ch0 CB SB 1 Ch0 D1 Ch0 D0 2 Res Ch1 CB SB 3 Ch1 D1 Ch1 D0 4 Res Ch2 CB SB 5 Ch2 D1 Ch2 D0 6 Res Ch3 CB SB 7 Ch3 D1 Ch3 D0 Conditions...

Страница 27: ...ocess data exchange 27 REG 0bin 5 3 1 Process data exchange Control byte in process data exchange REG 0 A gain and offset calibration of the terminal can be carried out with the control byte The code...

Страница 28: ...the point and rotated around this point B_h B_off G B_100 Offset compensation should therefore be carried out for PT100 at 100 or PT1000 at 1000 Gain compensation is then carried out independently of...

Страница 29: ...R ROM R14 31 reserved 0x0000 R R15 31 Alignment register variable R W RAM R16 Hardware version number 0x R W SEEROM R17 31 Hardware compensation Offset specific R W SEEROM R18 31 Hardware compensation...

Страница 30: ...register The diagnostic register can contain additional diagnostic information Parity errors for instance that occur in serial interface terminals during data transmission are indicated here R6 Diagno...

Страница 31: ...s with variable logical channel length e g 60xx 0x13 Word array with variable logical channel length 0x14 Structure 1 byte n words with variable logical channel length 0x15 Double word array with vari...

Страница 32: ...ion is active When write protection is not active the code word is returned when the register is read If the write protection is active the register contains a zero value R32 Feature register This reg...

Страница 33: ...ge Process data 0 0 0 R33 to R47 Terminal specific registers The function of these registers depend on the respective terminal type see terminal specific register description R33 User scaling offset B...

Страница 34: ...ster is read without changing it The value can be found in the input process image Bit 6 1 The user data are written into a register The process is complete once the status byte in the input process i...

Страница 35: ...2 0x35 0xXX 0xDF The code word is set and the terminal returns the register address with bit 7 for register access as acknowledgment Byte Byte 3 Byte 2 Byte 1 Byte 0 Name DataIN 1 DataIN 0 Not used St...

Страница 36: ...Byte 2 DataOUT1 low byte 0xDF 1101 1111bin 0x12 0x35 Explanation Bit 0 7 set means Register communication switched on Bit 0 6 set means writing to the register Bits 0 5 to 0 0 specify the register nu...

Страница 37: ...ple The bits of the feature register change the properties of the terminal and have a different meaning depend ing on the type of terminal Refer to the description of the feature register of your term...

Страница 38: ...OUT1 low byte 0xDF 1101 1111bin 0x00 0x00 Explanation Bit 0 7 set means Register communication switched on Bit 0 6 set means writing to the register Bits 0 5 to 0 0 specify the register number 31 with...

Страница 39: ...ents there Beckhoff Support Support offers you comprehensive technical assistance helping you not only with the application of individual Beckhoff products but also with other wide ranging services su...

Страница 40: ...15 Fig 6 Disassembling of terminal 16 Fig 7 Power contact on left side 17 Fig 8 Standard wiring 18 Fig 9 Pluggable wiring 18 Fig 10 High Density Terminals 19 Fig 11 Connecting a cable on a terminal p...

Страница 41: ......

Страница 42: ...Beckhoff Automation GmbH Co KG H lshorstweg 20 33415 Verl Germany Phone 49 5246 9630 info beckhoff com www beckhoff com...

Отзывы: