Product overview
KL26xx/KS26xx
16
Version: 2.5.0
2.2.1
Technical data
Technical data
KL2612, KS2612
Number of outputs
2 x change-over
Contact material
Gold-plated silver alloy
Nominal voltage
125 V
AC
/ 30 V
DC
Load type
ohmic
Max. output current
2 A per channel
Maximum switching capacity
with ohmic load
Alternating voltage: 0.5 A / 125 V
AC
Direct voltage: 2 A / 30 V
DC
Minimum permitted load (guide value)
10 µA at 10 mV
Response times with nominal load
Max. response time 4 ms
Max. release time 4 ms
Max. bounce time 4 ms
Lamp load, control gear
Max. input inrush current 2 A
Electrical isolation
500 V (K-bus / field voltage)
K-Bus current consumption
60 mA
Bit width in process image
2 outputs
Switching cycles mech. (min.)
1 x 10
8
switching operations
Switching cycles electr. (min.)
10
5
switching operations, ohmic load
at 30 V
DC
, 2 A
or 125 V
AC
, 0.5 A
Permitted switching frequency at maximum
contact load
20 switching operations/min
Contact resistance max. (new)
< 40 mOhm
Insulation resistance (min.)
100 MOhm at 500 V
DC
Test voltage between open contacts
750 V (1 min. between open contacts)
Configuration
no address or configuration settings required
Special features
Signal relay
Weight
approx. 80 g
Dimensions (W x H x D)
15 mm x 100 mm x 70 mm (width aligned 12 mm)
on 35 mm mounting rail conforms to EN 60715
Permissible ambient temperature during
operation
0 °C ... +55 °C
Permissible ambient temperature during
storage
-25 °C ... +85 °C
Permissible relative humidity
95 %, no condensation
Vibration / shock resistance
conforms to EN 60068-2-6 / EN 60068-2-27
EMC immunity / emission
conforms to EN 61000-6-2 / EN 61000-6-4
Installation position
variable
Protection class
IP20
Approvals/markings
Ex marking
Standard
Marking
ATEX
II 3 G Ex nA IIC T4 Gc
Содержание KL26 Series. KS26 Series
Страница 1: ...Documentation EN KL26xx KS26xx Relais Output Terminals 2021 08 25 Version 2 5 0...
Страница 2: ......
Страница 4: ...Table of contents KL26xx KS26xx 4 Version 2 5 0...
Страница 46: ......