CoE objects
EP7402-0057
48
Version: 1.3
Index 8022: STM Features Channel 1
Index 8032: STM Features Channel 2
Access rights: read/write
Subindex
(hex)
Name
Description
Unit
Data type Default
11
Select info data 1
Define the measured values to be mapped to the input vari-
ables in “STM Synchron info data Channel n“
Enum:
• “Motor velocity” = 7
• “Motor load” (I
2
T value) = 11
dec
• “Motor amplifier I
2
T load” = 12
dec
• “Motor dc current” = 13
dec
• “Motor back EMF” = 17
dec
• “Motor restart counter” = 18
dec
• “Internal temperature” = 101
dec
• “Motor supply voltage” = 104
dec
-
USINT
7
dec
19
Select info data 2
-
USINT
11
dec
51
Select info data 3
-
USINT
13
dec