Commissioning and configuration
EP6224 and EP6228
40
Version: 1.5
5.3
Object description and parameterization
EtherCAT XML Device Description
The display matches that of the CoE objects from the EtherCAT
ommend downloading the latest XML file from the download area of the Beckhoff website and in-
stalling it according to installation instructions.
Parameterization via the CoE list (CAN over EtherCAT)
The EtherCAT device is parameterized via the CoE - Online tab (double-click on the respective ob-
ject) or via the Process Data tab (allocation of PDOs). Please note the following general CoE notes
when using/manipulating the CoE parameters:
- Keep a startup list if components have to be replaced
- Differentiation between online/offline dictionary, existence of current XML description
- use “CoE reload” for resetting changes
Introduction
The CoE overview contains objects for different intended applications:
• Objects required for parameterization during commissioning.
• Objects intended for regular operation, e.g. through ADS access.
• Objects for indicating internal settings (may be fixed).
• Profile specific objects, for exposition the status of the inputs and outputs.
The following section first describes the objects require for normal operation, followed by a complete
overview of other objects.
5.3.1
Objects for commissioning
Index 1011 Restore default parameters
Index (hex) Name
Meaning
Data type
Flags
Default
1011:0
Restore default param-
eters
Restore default parameters
UINT8
RO
0x01 (1
dec
)
1011:01
SubIndex 001
If this object is set to "
0x64616F6C"
in the set value di-
alog, all backup objects are reset to their delivery state.
UINT32
RW
0x00000000
(0
dec
)