EJ40xx - LEDs
Fig. 14: EJ40xx - LEDs
LED
Color Display
State
Description
RUN
green off
Init
State of the EtherCAT State Machine:
INIT
= initialization of
the plug-in module
flashing
Pre-Operational State of the EtherCAT State Machine:
PREOP =
function for
mailbox communication and different default settings set
single flash Safe-
Operational
State of the EtherCAT State Machine:
SAFEOP
= verification
of the Sync Manager channels and the distributed clocks.
Outputs remain in safe state
on
Operational
State of the EtherCAT State Machine:
OP =
normal operating
state; mailbox and process data communication is possible
flickering
Bootstrap
State of the EtherCAT State Machine:
BOOTSTRAP
=
Up
green off
-
No 24 V
DC
power supply connected
on
-
24 V
DC
power supply connected