Product overview
CPX39xx-0010
21
Version: 0.1
4.4.2
CP-Link 4 Input (X102)
X102
SG 8-pole M12 built-in-IP67 METZ connect CAT6Ads
The Control Panel is connected with the transmitter box CU8802/ CU8803 via the CP-Link 4 Input (
X102
).
Pin
Signal
Pin
Signal
1
CP-Link 4_0P
5
CP-Link 4_3P
2
CP-Link 4_0N
6
CP-Link 4_3N
3
CP-Link 4_1P
7
CP-Link 4_2N
4
CP-Link 4_1N
8
CP-Link 4_2P
4.4.3
Ground
Malfunction possible with missing ground connection
A proper ground connection of the device is absolutely necessary for the correct function of the
touchscreen.
The Control Panel is grounded via the screw connection (
Ground
).
A wire cross section of min. 4 mm
2
is required.