background image

Product Description 

 

 

2.6.2 USB-adapter cable 

The provided Y-adapter cable enables connecting two peripheral USB devices to the Panel PC. 

2.6.3  Optional Ethernet connection cables 

The following Ethernet connection cables are available: 

Patch cable 

Cable CAT 5, RJ45 connector, second end RJ45 IP67 

C9900-K605 

Patch cable CAT 5, 5 m length 

C9900-K606 

Patch cable CAT 5, 10 m length 

C9900-K607 

Patch cable CAT 5, 20 m length 

C9900-K608 

Patch cable CAT 5, 30 m length 

C9900-K609 

Patch cable CAT 5, 40 m length 

C9900-K610 

Patch cable CAT 5, 50 m length 

 
 

2.6.4  Optional Ethernet connectors 

With order option C9900-K557 two RJ45 connectors IP67 can be ordered to configure individual 
connection cables. 
 

16

 

CP770x-140x 

Содержание CP770 140 Series

Страница 1: ...Installation and Operating instructions for CP770x 140x IP65 Stainless steel Panel PC Version 1 4 Date 2018 07 11...

Страница 2: ......

Страница 3: ...e Use 9 2 3 Opening the connection area 9 2 4 Access to the memory device and the battery 10 2 4 1 Removing the rear cover 10 2 4 2 Replacing the battery 11 2 5 Connections 12 2 5 1 2 Port USB Interfa...

Страница 4: ...Emergency stop button and electromechanical push buttons in the front 22 5 3 Servicing and maintenance 23 5 3 1 Cleaning 23 5 3 2 Maintenance 23 5 3 3 Replacing the battery of the motherboard 23 5 4...

Страница 5: ...are registered trademarks of and licensed by Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the...

Страница 6: ...ls Risk of injury WARNING If you do not adhere the safety advise adjoining this symbol there is danger to life and health of individuals Hazard to individuals CAUTION If you do not adhere the safety a...

Страница 7: ...l parts of the equipment must first be switched off after which the Panel PC is to be disconnected from the equipment Disconnect the device by unplugging the connectors on the rear side of the Panel P...

Страница 8: ...pen the housing of the Panel PC Note For technical support contact Beckhoff Service 1 4 1 National regulations Depending on the type of machine and plant in which the Industrial PC is used national re...

Страница 9: ...Product Description 2 Product Description 2 1 Product overview Front view of CP770x 1400 Front view of CP770x 1401 with USB port emergency stop button and electromechanical push buttons CP770x 140x 7...

Страница 10: ...r the following benefits Flush mounted touch screen Stainless steel housing 1 4301 matt ground with grain size 240 protection class IP65 Front laminate with slide in logo Flush mounted integrated stai...

Страница 11: ...rotatable mounting arm adapter is available Risk of explosion Danger The Control Panel must not be used where there is a risk of explosion 2 3 Opening the connection area The connectors of the Panel...

Страница 12: ...ed through the mounting arm tube before connecting them in the connection area The installation of the cover takes place in reverse order 2 4 Access to the memory device and the battery 2 4 1 Removing...

Страница 13: ...rse order Observe the correct tightening torque Attention Tighten the screws with a torque of 0 7 Nm 2 4 2 Replacing the battery Danger of Explosion WARNING Replace battery only with the identical typ...

Страница 14: ...ower Supply emergency stop and push buttons X100 2 Port USB 2 5 1 2 Port USB Interface X100 X100 SG 8POL M9 built in PCB sold IP67 BINDER BINDER 09 0427 30 08 SERIES 712 M9X0 5 The Panel PC is equippe...

Страница 15: ...tton S3 push button S4 The power supply connection of the Panel PC and the connection of the emergency stop button and the electromechanical push buttons are established via the 19 pole M20 XS01 conne...

Страница 16: ...000 Mbit The RJ 45 sockets X 102 X 103 enable connection of the Panel PC to an 10 100 1000 Mbit Ethernet network While using the FBS RJ45 8 GS connector 534494 Fa Festo AG Co KG the protection class a...

Страница 17: ...ncy stop button and the push buttons XS01 as well as RJ45 connectors and prefabricated Ethernet connection cables are available 2 6 1 Connection Cables for Power Supply Emergency Stop and Push Buttons...

Страница 18: ...CAT 5 RJ45 connector second end RJ45 IP67 C9900 K605 Patch cable CAT 5 5 m length C9900 K606 Patch cable CAT 5 10 m length C9900 K607 Patch cable CAT 5 20 m length C9900 K608 Patch cable CAT 5 30 m l...

Страница 19: ...sture condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur a delay time of approximately 12 hou...

Страница 20: ...ting arm adapter for Control Panel CP770x 140x Stainless steel 1 4301 matt ground mounting arm installation from the top 4 1 1 Welding the mounting arm tube The junction of the mounting arm adapter ha...

Страница 21: ...e for mounting arm installation In order to ensure better mobility of the mounting arm adapter lubricate the O rings and all parts which have contact with the O rings with the PTFE grease Lubricate a...

Страница 22: ...ely O rings 2 1 The picture shows the assembly of the rotatable mounting arm adapter which first must be frozen with the customized mounting arm see chapter Welding the mounting arm tube Now the adapt...

Страница 23: ...pull the cable 4 2 1 Connecting cables The connections are located at the rear of the Panel PC and are documented in the chapter Connections When connecting cables to the Panel PC please adhere to th...

Страница 24: ...thing to the CF card every few seconds so that the probability of causing damage by switching off while the software is running is very high Switch off power supply Warning When you have shut down the...

Страница 25: ...ce correct polarity Handling of Lithium Batteries WARNING Lithium Batteries should not be recharged exposed to fire opened and they should be protected against sunlight and moisture The used battery m...

Страница 26: ...ot connected Check power supply cable 1 Correctly connect cable 2 Call Beckhoff Service Panel PC boots software starts but control does not operate correctly The cause of the error is in the software...

Страница 27: ...Assembly dimensions 7 Assembly dimensions Notice mounting orientation Warning The assembly of the unit must take place with the orientation diagrammed here CP770x 140x 25...

Страница 28: ...Assembly dimensions Notice mounting orientation Warning The assembly of the unit must take place with the orientation diagrammed here 26 CP770x 140x...

Страница 29: ...Assembly dimensions Notice mounting orientation Warning The assembly of the unit must take place with the orientation diagrammed here CP770x 140x 27...

Страница 30: ...Assembly dimensions Notice mounting orientation Warning The assembly of the unit must take place with the orientation diagrammed here 28 CP770x 140x...

Страница 31: ...Assembly dimensions Notice mounting orientation Warning The assembly of the unit must take place with the orientation diagrammed here CP770x 140x 29...

Страница 32: ...Assembly dimensions Notice mounting orientation Warning The assembly of the unit must take place with the orientation diagrammed here 30 CP770x 140x...

Страница 33: ...Assembly dimensions Notice mounting orientation Warning The assembly of the unit must take place with the orientation diagrammed here CP770x 140x 31...

Страница 34: ...Assembly dimensions Notice mounting orientation Warning The assembly of the unit must take place with the orientation diagrammed here 32 CP770x 140x...

Страница 35: ...Assembly dimensions Notice mounting orientation Warning The assembly of the unit must take place with the orientation diagrammed here CP770x 140x 33...

Страница 36: ...Wiring Diagram 8 Wiring Diagram Emergency stop button and electromechanical push buttons 34 CP770x 140x...

Страница 37: ...4 A according to UL 60950 2 chapter 2 5 table 2C Interfaces CP770x 1400 2 x RJ 45 Ethernet 10 100 1000 Mbit 2 Port USB 2 0 Interfaces CP770x 1401 2 x RJ 45 Ethernet 10 100 1000 Mbit 2 Port USB 2 0 Add...

Страница 38: ...Co KG Huelshorstweg 20 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 E mail info beckhoff de Web http www beckhoff de Beckhoff Support Support offers you comprehensive technical assis...

Страница 39: ...generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this...

Отзывы: