Product Description
12
CP37xx
2.4.2 Power Supply (X102)
X102
Connector 12-pole Coninvers RC-12P1N1126000
View connector-sided
The power supply connection of the Panel PC and the connection with the UPS (optional) is established
via the 12-pole power supply socket (
X102
). The protection class of the circular plug-in connector accords
to the IP65-standard.
Wiring when using 8-core cables:
Pin
Wire
Function
Pin
Wire
Function
1
1
-
Battery Pack
(with UPS)
7
6
PC_ON
2
2
+
8
7
Power-Status
3
3
NC
9
-
NC
4
ge/gn
10
-
NC
5
4
-
24 V DC Power Supply
11
-
NC
6
5
+
12
-
NC
Wiring when using 12-core cables:
To connect the power supply and the battery pack, 2 wires per pin are used when using 12-core cables to
halve the voltage drop across the cable.
Pin
Wire
Function
Pin
Wire
Function
1
1, 8
-
Battery Pack
(with UPS)
7
6
PC_ON
2
2, 9
+
8
7
Power-Status
3
3
NC
9
-
NC
4
ge/gn
10
-
NC
5
4, 10
-
24 V DC Power Supply
11
-
NC
6
5, 11
+
12
-
NC
2.4.3 Additional interfaces (optional)
There are notes at the Panel PC and in the connection area which provide information about the
hardware configuration of the Panel PC at the time it was supplied.
2.4.4 Ground connection
The Panel PC is grounded via the screw connection.
Note
Malfunction possible with missing ground connection
A proper ground connection of the device is absolutely necessary for the correct
function of the touchscreen.