background image

Product overview

CP29xx-2xxx-0000

13

Version: 1.2

3.4

Connection cables/connection kits

The following connection cables and ready-made connection kits are available for the CP29xx-2xxx-0000:

Table 6: Connection cables/kits CP29xx

Connection cables/connection kits

Description

C9900-K774

Connection kit 1 m, includes: 1 m display port to DVI
cable, 1 m USB cable

C9900-K775

Connection kit 3 m, includes: 3 m display port to DVI
cable, 3 m USB cable

C9900-K776

Connection kit 5 m, includes: 5 m display port to DVI
cable, 5 m USB cable

C9900-K780

Display port connection cable for DVI-D display cable
1 m

C9900-K781

Display port connection cable for DVI-D display cable
3 m

C9900-K782

Display port connection cable for DVI-D display cable
5 m

C9900-K554

Connection cable USB-2.0 A-B, 1 m

C9900-K552

Connection cable USB-2.0 A-B, 3 m

C9900-K553

Connection cable USB-2.0 A-B, 5 m

Ready-made connection kits for DVI/USB connection are available as an option. They are included as
standard when you order the C6030 as an option for mounting at the back of the Control Panel. They can
also be ordered separately from Beckhoff sales, quoting the following article descriptions:

Table 7: Connection kits CP29xx with C6030

Connection kit

DVI/USB connection

C9900-K783

Display port connection cable for DVI-D display cable
0.33 m

C9900-K784

Connection cable USB-2.0 A-B, 0.37 m

C9900-K790

Power supply cable adapter for shared use of
C6030-2xxx-00x0 and CP29xx-2xxx-000

Содержание CP29 -2 -0000 Series

Страница 1: ...Manual EN CP29xx 2xxx 0000 Control Panel 4 8 2021 Version 1 2...

Страница 2: ......

Страница 3: ...ection cables connection kits 13 4 Commissioning 14 4 1 Transport and storage 14 4 2 Installation in the control cabinet 15 4 2 1 Dimensions 15 4 2 2 C6030 installation 17 4 2 3 Installation in the co...

Страница 4: ...Table of contents CP29xx 2xxx 0000 4 Version 1 2...

Страница 5: ...AT EtherCAT EtherCAT P Safety over EtherCAT TwinSAFE XFC and XTS are registered and licensed brands of Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use...

Страница 6: ...safety notice may lead to minor injuries Warning of damage to property NOTE Disregarding the notice may lead to damage to property 2 2 Intended use The CP29xx multi touch built in Control Panel is de...

Страница 7: ...ssipation please refer to the respective data sheet Ensure that only trained qualified persons with a control and automation technology background operate the device Use by unauthorized persons can le...

Страница 8: ...ety ranges from different display sizes and formats to custom models This Panel generation is also ideally suited for single touch applications The Control Panel has the following features Different d...

Страница 9: ...d plant engineering 4 Mounting plate for C6030 Part of the C6030 Plate for mounting the Industrial PC at the back of the Control Panel 5 Fastening points for C9900 K790 Attaching the power supply cabl...

Страница 10: ...l wiring of the Control Panel X101 1 2 3 4 5 Fig 2 CP29xx_voltage connector pin numbering Table 2 Voltage connector pin assignment Pin Description Function 1 NC 2 NC 3 4 GND 0 V 5 24 V Power supply Th...

Страница 11: ...ple 9 StdA_SSTX Orange 3 2 3 DVI The Control Panel has a DVI interface X106 It is used to transmit the video signal from the Industrial PC to the Control Panel The graphics signal is transmitted direc...

Страница 12: ...ate No Description 1 Model 2 FCC approval 3 Serial number BTN 4 Date of manufacture 5 Display 6 Touch screen 7 Power supply unit 24 VDC NEC class 2 8 DVI interface X106 9 USB interface X104 10 Groundi...

Страница 13: ...ection cable for DVI D display cable 3 m C9900 K782 Display port connection cable for DVI D display cable 5 m C9900 K554 Connection cable USB 2 0 A B 1 m C9900 K552 Connection cable USB 2 0 A B 3 m C9...

Страница 14: ...the components are sensitive to strong vibrations and impacts During transport the device must therefore be protected from mechanical stress Appropriate packaging of the Panel PC in particular the ori...

Страница 15: ...ing chapters 4 2 1 Dimensions The dimensions of the Control Panel are used to prepare the control cabinet and to ensure that the Panel is correctly mounted in the control cabinet If you want to mount...

Страница 16: ...7 x y t cut out dimensions x y r t r 450 380 1 5 2 5 2 Fig 8 CP29xx_dimensions 19 inch Fig 9 shows the dimensions of the Control Panel with 21 5 inch display 559 377 7 7 51 5 x y t cut out dimensions...

Страница 17: ...The housing of the Control Panel comes prepared with the mounting holes for the C6030 These are located at the back of the device see locations marked in Fig 10 Fig 10 CP29xx_without C6030 The holes a...

Страница 18: ...creen are avoided as far as possible For the correct installation height use the position of the screen for guidance This should always be optimally visible to the user Do not expose the Control Panel...

Страница 19: ...cabinet Connected devices that have their own power supply must have the same potential for PE and GND as the Industrial PC system no potential difference 4 3 1 Installing the supply cable Install th...

Страница 20: ...Commissioning CP29xx 2xxx 0000 20 Version 1 2 A B C D Fig 14 CP29xx_assembly of strain relief housing...

Страница 21: ...an lead to hardware damage due to electromagnetic in terference Only use the device with functional earthing Electromagnetic compatibility EMC refers to the Industrial PC s ability not to interfere wi...

Страница 22: ...l Panel 21 and then plug in all data transmission cables Connecting the power supply Cables with a maximum cable cross section of 1 5 mm2 must be used for connecting the power supply To achieve the lo...

Страница 23: ...a thunderstorm can lead to electric shocks Never disconnect the cables of the of the Control Panel during a thunderstorm Before you remove the Control Panel you must follow the steps below 1 Shut dow...

Страница 24: ...C You can now remove the Panel from the control cabinet 3 To reattach the clamping levers to the housing retighten them with the Allen key section D A B C D Fig 15 CP29xx_removal from the control cabi...

Страница 25: ...T display and anomalies of the touch screen sensor are production related and do not constitute grounds for complaint Cleaning NOTE Unsuitable cleaning agents The use of unsuitable cleaning agents can...

Страница 26: ...outside the Industrial PC Call the machine or software manufacturer Malfunction of the touch screen Poor or missing ground connection of the device Poor or missing ground connection of the user Establ...

Страница 27: ...Front side IP65 rear side IP20 Vibration resistance sinusoidal vibration EN 60068 2 6 10 to 58 Hz 0 035 mm 58 to 500 Hz 0 5 G 5 m s2 Shock resistance shock EN 60068 2 27 5 G 50 m s2 duration 30 ms EMC...

Страница 28: ...r which you can find on the name plate Beckhoff Support Support offers you comprehensive technical assistance helping you not only with the application of individual Beckhoff products but also with ot...

Страница 29: ...al environment This device generates uses and may emit radio frequency energy and may cause adverse interference with radio communications if it is not installed and used in accordance with the operat...

Страница 30: ......

Страница 31: ...Beckhoff Automation GmbH Co KG H lshorstweg 20 33415 Verl Germany Phone 49 5246 9630 info beckhoff com www beckhoff com...

Отзывы: