Product overview
CP29xx-2xxx-0000
11
Version: 1.2
3.2.2
USB
The Control Panel has a USB 3.0 interface (X104) that supports the USB 3.0 specification. The Control
Panel is connected to the Industrial PC via the USB input.
1 2
3
4
X104
Fig. 3: CP29xx_USB interface pin numbering
Table 3: USB interface pin assignment
Pin
Connection
Typical assignment
Shell
Shield
Drain Wire
1
VBUS
Red
2
D -
White
3
D +
Green
4
GND
Black
5
StdA_SSRX -
Blue
6
Std
Yellow
7
GND_DRAIN
N/A
8
StdA_SSTX -
Purple
9
Std
Orange
3.2.3
DVI
The Control Panel has a DVI interface (X106). It is used to transmit the video signal from the Industrial PC to
the Control Panel.
The graphics signal is transmitted directly over a maximum distance of 5 m. The Industrial PC requires a
conventional DVI output. The resolution at the Control Panel depends on the distance from the display
device.
1
9
17
8
16
24
X106
Fig. 4: CP29xx_DVI interface pin numbering
Table 4: DVI interface pin numbering
Pin
Signal
Pin
Signal
Pin
Signal
1
Rx2-
9
Rx1-
17
Rx0-
2
Rx2+
10
Rx1+
18
Rx0+
3
GND
11
GND
19
GND
4
Rx4-
12
Rx3-
20
Rx5-
5
Rx4+
13
Rx3+
21
Rx5+
6
DDC CLK
14
+ 5V DVI
22
GND
7
DDC DAT
15
GND
23
RxC+
8
AV SYNC
16
HPD
24
RxC-
Содержание CP29 -2 -0000 Series
Страница 1: ...Manual EN CP29xx 2xxx 0000 Control Panel 4 8 2021 Version 1 2...
Страница 2: ......
Страница 4: ...Table of contents CP29xx 2xxx 0000 4 Version 1 2...
Страница 20: ...Commissioning CP29xx 2xxx 0000 20 Version 1 2 A B C D Fig 14 CP29xx_assembly of strain relief housing...
Страница 30: ......