Serial Ports COM2 through COM4
Chapter:
Connectors
Beckhoff New Automation Technology
CB3052
page 37
3.17 Serial Ports COM2 through COM4
There are three more serial interfaces on the board. Of these, COM3 is available through the power
connector (cf. p. 19). COM2 and COM4 and made available via a 2x5 pin connector each (JST
B10B-PHDSSLFSN, mating connector: PHDR-10VS). However, if the board has a touch screen interface,
COM4 is used internally. On these boards, the COM4 connector is either not populated or it is used for
mouse and keyboard signals (see pinning below). Signals default to RS232 level but can be ordered as TTL
level also.
The port address and the interrupt are set via the BIOS setup.
Description
Name
Pin
Name
Description
data carrier detect
DCD
1
6
DSR
data set ready
receive data
RXD
2
7
RTS
request to send
transmit data
TXD
3
8
CTS
clear to send
data terminal ready
DTR
4
9
RI
ring indicator
ground
GND
5
10
VCC
5 volt supply
Alternative pinout of COM-connector when touchscreen feature is present:
Description
Name
Pin
Name
Description
keyboard clock
KCLK
1
6
MCLK
mouse clock
keyboard data
KDAT
2
7
MDAT
mouse data
reserved
N/C
3
8
N/C
reserved
reserved
N/C
4
9
N/C
reserved
ground
GND
5
10
VCC
5 volt supply
Содержание CB3063
Страница 2: ......
Страница 5: ...Notes on the Documentation Chapter Document History Beckhoff New Automation Technology CB3052 page 5...
Страница 26: ...Chapter Connectors VGA DVI page 26 Beckhoff New Automation Technology CB3052 Pin Name Description C5 GND ground...
Страница 78: ...Annex Post Codes page 78 Beckhoff New Automation Technology CB3052...