background image

Mounting

C9900-G070 and C9900-G071

17

Version: 1.0

4

Mounting

4.1

Installing the labels

The blank label sheets for the push-buttons of the push-button extension offered under order code C9900-
Z260 can be printed with a conventional office printer and then inserted in the push-button extension.

Содержание C9900-G070

Страница 1: ...Installation and Operating instruction C9900 G070 and C9900 G071 Push button extension for 7 inch Economy built in Panel 1 0 26 04 2019 Version Date ...

Страница 2: ......

Страница 3: ...ls 16 4 Mounting 17 4 1 Installing the labels 17 4 2 Installing the Wago picoMax connector system 18 5 Operation 19 5 1 Switching the Control Panel on and off 19 5 1 1 Switching on 19 5 1 2 Shutting down and switching off 19 5 2 Operation 19 5 3 Maintenance 19 5 3 1 Cleaning 19 5 3 2 Maintenance 19 5 3 3 Emergency procedures 20 5 3 4 Decommissioning 20 6 TwinCAT System Manager 21 7 Dimensional dra...

Страница 4: ...Table of contents C9900 G070 and C9900 G071 4 Version 1 0 ...

Страница 5: ... diagrams and descriptions in this documentation Trademarks Beckhoff TwinCAT EtherCAT EtherCAT P Safety over EtherCAT TwinSAFE XFC and XTS are registered trademarks of and licensed by Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owners Patent Pending The EtherCAT Technology i...

Страница 6: ...ing who are familiar with the applicable national standards Description of symbols In this documentation the following symbols are used with an accompanying safety instruction or note The safety instructions must be read carefully and followed without fail DANGER Serious risk of injury Failure to follow the safety instructions associated with this symbol directly endangers the life and health of p...

Страница 7: ... or is exposed to extreme variations in tempera ture make sure that moisture condensation does not form on or inside the device 2 2 Unpacking Proceed as follows to unpack the unit 1 Remove packaging 2 Do not discard the original packaging Keep it for future relocation 3 Check the delivery for completeness by comparing it with your order 4 Please keep the associated paperwork It contains important ...

Страница 8: ...o NC contacts can be used by the customer The push buttons S2 green and S4 blue each actuate two NO contacts of which one is relayed to the controller and one is available as a potential free contact for use by the customer The push button S3 red actuates an NC contact and an NO contact The NO contact is relayed to the controller the NC contact is available as a potential free contact for use by t...

Страница 9: ...elivered with green red and blue push button caps Other push button cap color options are available for retrofitting see chapter Accessories 16 A label sheet with 54 pre punched button labels is available under order code C9900 Z260 Installation is explained in chapter Installing the labels 17 ...

Страница 10: ... with one normally open contact to a terminal row Additionally all push buttons are transmitted with a normally open contact via USB The LEDs of the push buttons are controlled via USB only C9900 G071 Push button extension for CP6x06 with horizontal 7 inch display push button extension on the bottom side 3 push button keys with signal lamp type RAFI RAFIX 22FS round 30 mm 1 emergency stop key type...

Страница 11: ... plant engineering applications The push button extension is located below the touchscreen NOTE Risk of explosion The built in Panels must not be used in potentially explosive atmospheres 3 4 Accessing the connections The connections of the push button extension for use by the customer are located at the bottom of the housing 3 4 1 C9900 G070 connections X2 Wago 6 pin X1 Wago 4 pin ...

Страница 12: ...Product description C9900 G070 and C9900 G071 12 Version 1 0 3 4 1 1 C9900 G070 circuit diagram Fig 1 C9900 G070 ...

Страница 13: ...rgency stop 4 X1 4 NO contact emergency stop Connection strip Terminal point Description X2 1 X2 1 NO contact S4 blue 2 X2 2 NO contact S4 blue 3 X2 3 NC contact S3 red 4 X2 4 NC contact S3 red 5 X2 5 NO contact S2 green 6 X2 6 NO contact S2 green NOTE Electrical characteristic values of the operating elements The electrical characteristic values of the emergency stop and push button contacts must...

Страница 14: ...Product description C9900 G070 and C9900 G071 14 Version 1 0 3 4 2 C9900 G071 connections X3 Wago 12 pin X2 Wago 6 pin X1 Wago 4 pin 3 4 2 1 C9900 G071 circuit diagram Fig 2 C9900 G071 ...

Страница 15: ...ct S3 red 4 X2 4 NC contact S3 red 5 X2 5 NO contact S2 green 6 X2 6 NO contact S2 green Connection strip Terminal point Description X3 1 GND Supply Power 2 24 VDC Supply Power 3 X3 3 24 V LED blue 4 X3 4 24 V LED red 5 X3 5 24 V LED green 6 N C 7 X3 7 NO contact S4 blue 8 X3 8 NO contact S4 blue 9 X3 9 NC contact S3 red 10 X3 10 NC contact S3 red 11 X3 11 NO contact S2 green 12 X3 12 NO contact S...

Страница 16: ...afi FS diameter 22 3 mm 5 pcs C9900 Z257 Push button cap green for individual application to a C9900 G0xx push button extension type Rafi FS diameter 22 3 mm 5 pcs C9900 Z258 Push button cap red for individual application to a C9900 G0xx push button extension type Rafi FS diameter 22 3 mm 5 pcs C9900 Z259 Push button cap clear for individual application to a C9900 G0xx push button extension type R...

Страница 17: ... 1 0 4 Mounting 4 1 Installing the labels The blank label sheets for the push buttons of the push button extension offered under order code C9900 Z260 can be printed with a conventional office printer and then inserted in the push button extension ...

Страница 18: ...onnection consists of male connector and female connector with grip plate and release slide 1 2 Disconnect the plug connection with the release slide 1 Open the locking device latch by pushing down the release slide on the grip plate 2 Pull out the female connector with the grip plate from the male connector ...

Страница 19: ... data to the data storage device automatically at intervals of a few seconds for which reason there is a very high probability of causing damage by switching off while software is running NOTE Switching off the Industrial PC Once you have shut down the Industrial PC you must switch it off for at least 10 seconds in order to be able to restart it After switching on the power supply again the Indust...

Страница 20: ...crap regulations When disposing of the device follow the national electronic scrap regulations In order to dispose of the device it must be removed and fully dismantled Housing components polycarbonate polyamide PA6 6 are suitable for plastic recycling Metal parts can be sent for metal recycling Electronic parts such as disk drives and circuit boards must be disposed of in accordance with national...

Страница 21: ...e view on the left click on I O and then right click on Device 3 In the context menu click on Scan The New I O Devices window appears All available devices are displayed 4 Select the devices you want to use and confirm the selection with OK 5 Confirm the request with Yes in order to look for boxes 6 Confirm the request whether to enable FreeRun with Yes ð The device is inserted as a box in the tre...

Страница 22: ...TwinCAT System Manager C9900 G070 and C9900 G071 22 Version 1 0 Term label after activating FreeRun Term label after processing ...

Страница 23: ...Dimensional drawing C9900 G070 and C9900 G071 23 Version 1 0 7 Dimensional drawing 7 1 Dimensional drawing CP6x06 with C9900 G070 or C9900 G071 Fig 3 External dimension ...

Страница 24: ...Dimensional drawing C9900 G070 and C9900 G071 24 Version 1 0 Fig 4 Installation dimension ...

Страница 25: ...ollar Conductor cross section Stranded wire 0 25 1 5 mm with ferrule without plastic collar Conductor AWG 24 14 Strip length 8 9 mm 0 31 0 35 in Properties of the push button extension Protection class Front IP54 rear IP20 Shock resistance sinusoidal vibration EN 60068 2 6 10 to 58 Hz 0 035 mm 58 to 500 Hz 0 5 G 5 m s2 Shock resistance Shock EN 60068 2 27 5 G 50 m s2 duration 30 ms EMC interferenc...

Страница 26: ... Beckhoff components there Beckhoff Headquarters Beckhoff Automation GmbH Co KG Huelshorstweg 20 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 e mail info beckhoff com Beckhoff Support Support offers you comprehensive technical assistance helping you not only with the application of individual Beckhoff products but also with other wide ranging services support design programming a...

Страница 27: ...st adverse interference if the device is used in a commercial environment This device generates uses and may emit radio frequency energy and may cause adverse interference with radio communications if it is not installed and used in accordance with the operating instructions If this device is used in a residential area it is likely to cause adverse interference in which case the user must take app...