General instructions 

 

 
 

Operator's obligation to exercise diligence 

 

The operator must ensure that 

• 

the Industrial PC is only used for its intended use (see also 

Product Description

). 

• 

the Industrial PC is in a sound condition and in working order 
during operation. 

• 

the operation manual is in good condition and complete, and 
always available for reference at the location of the Industrial PC. 

• 

the Industrial PC is operated, maintained and repaired only by 
sufficiently qualified and authorised personnel. 

• 

the personnel is instructed regularly about relevant occupational 
safety and environmental protection aspects, and is familiar with 
the operating manual and in particular the safety notes contained 
herein. 

• 

none of the safety and warning notes attached to the Industrial PC 
are removed, and that all notes remain legible. 

 

National regulations  
depending on the machine 
type 

Depending on the type of machine and plant in which the Industrial PC is 
being used, there will be national regulations for the control of such 
machines and plant that the operator must observe. These regulations 
cover, amongst other things, the intervals between inspections of the 
controller. 
 
The operator must initiate such inspections in good time. 
 

 

Warning

 

 

Only trained persons may open the Industrial PC housing! 

The operator is responsible for ensuring that only trained electrical staff 
opens the housing of the Industrial PC. 
 

 

 

Procedure in the event of a 
fault 

In the event of a fault in the Industrial PC, appropriate measures can be 
determined with the aid of the list in the 

Fault correction

 section. 

 

 

Operator requirements 

Read the operating 
instructions 

Every user of the Industrial PC must have read these operating 
instructions. 
 

Software knowledge 

Every user must be familiar with any of the functions of the software 
installed on the PC that he can reach. 
 

 

C6640, C6650 

Содержание C6640

Страница 1: ...Installation and Operating instructions for Control Cabinet Industrial PC C6640 C6650 Version 1 1 Date 2010 04 08...

Страница 2: ......

Страница 3: ...1 Earthing measures 11 Power Supply Connection with 100 240 VAC power supply unit 12 Mains Socket 12 Power supply cords 12 Power Supply Connection with 24 VDC power supply unit optional 13 Beckhoff po...

Страница 4: ...arters 23 Beckhoff Support 23 Beckhoff Service 23 Assembly dimensions 24 C6640 Configuration with 100 240 VAC Power Supply 24 C6640 Configuration with 24 VDC Power Supply optional 25 C6650 Configurati...

Страница 5: ...meaning of 443 BGB of the German Civil Code or a statement about the contractually expected fitness for a particular purpose in the meaning of 434 par 1 sentence 1 BGB In the event that it contains te...

Страница 6: ...he plant Pulling out the fieldbus connection plug uncouples the PC optional Items of equipment that have been switched off must be secured against being switched on again The Industrial PC s power sup...

Страница 7: ...al regulations depending on the machine type Depending on the type of machine and plant in which the Industrial PC is being used there will be national regulations for the control of such machines and...

Страница 8: ...applications Opening the Housing View of the C6650 configuration with 100 240 VAC power supply The housing cover is locked by a latch After pressing the key 1 the cover can be fold up a little in the...

Страница 9: ...ing cover Now the housing cover can be taken off completely so providing access to the components The reassembly of the cover takes place in reverse order Ensure that the cover engages into the slides...

Страница 10: ...configuration options of the motherboard are available Order option Intel Celeron M Intel Pentium M Intel Core Duo Intel Core 2 Duo Intel Core 2 Quad C6640 0000 1 5 GHz 1 8 GHz C6640 0010 2 0 GHz 2 1...

Страница 11: ...interfaces USB1 USB4 The four USB interfaces X108 X111 are used to connect peripheral devices with USB connections The USB2 0 standard is supported Network connection 10 100MBit Network 10 100MBit Th...

Страница 12: ...in temperature make sure that moisture condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur a d...

Страница 13: ...bove and below the housing must be at least 50 mm in order to ensure adequate ventilation of the PC Warning Extreme environmental conditions should be avoided as far as possible Protect the PC from du...

Страница 14: ...at the PC housing main switch mains socket Power supply cords Power cords Europe In the area Europe you use the provided cable with inlet connector for non heating apparatus to connect the Industrial...

Страница 15: ...ach addresses this problem and now offers the user the option of switching the PC off without the need for using the battery thereby reducing the load on the battery In addition to the main switch thi...

Страница 16: ...ower supply unit Current loading maximum 5 V 14 A 5 V 0 3 A 12 V 12 A 12 V 0 5 A 3 3 V 12 A 5 V VSB 1 5 A Pin assignment of the connectors Two 5 pin plug connectors with CAGE CLAMP connection see phot...

Страница 17: ...terials for assembly of the connector Female plug connector 5 pole Strain relief housing 1 2 3 4 5 A B C D Fitting the connector Fitting the connector to the cable The plug is fitted to the cable as f...

Страница 18: ...C_ON signal is inverted i e the PC shuts down if the 24 V connection is live If the PC_ON input is NOT connected by the user the PC can be booted in the familiar way by connecting the supply voltage a...

Страница 19: ...g to the wiring diagram the circuit of PC_ON and Power Status is symbolical Wiring diagram power supply and external switch i Note The battery pack can only be connected when the Industrial PC is prov...

Страница 20: ...ndustrial PC and to the devices that are to be connected Connect all data transfer cables if present to the appropriate plug in receptacles of the data telecommunication networks Reconnect all devices...

Страница 21: ...Warning First shut down then switch off the PC If the Industrial PC is switched off as the software is writing a file to the hard disk the file will be destroyed Control software typically writes som...

Страница 22: ...sion if battery is incorrectly replaced Replace only with same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Replacing the f...

Страница 23: ...Industrial PC On delivery of the Beckhoff Industrial PC with operating system the software is already installed Should the software not be installed on your PC the drivers can be installed from the dr...

Страница 24: ...d press any key Check the setup settings Call Beckhoff Service Computer boots software starts but control does not operate correctly Cause of the fault is either in the software or in parts of the pla...

Страница 25: ...tra e 5 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 e mail info beckhoff com Beckhoff Support Beckhoff offers you comprehensive technical assistance helping you not only with the ap...

Страница 26: ...sions The following pages show diagrams of the Industrial PC with dimensions in mm C6640 Configuration with 100 240 VAC Power Supply Warning The assembly of the unit must take place with the orientati...

Страница 27: ...Assembly dimensions C6640 Configuration with 24 VDC Power Supply optional Warning The assembly of the unit must take place with the orientation diagrammed here C6640 C6650 25...

Страница 28: ...Assembly dimensions C6650 Configuration with 100 240 VAC Power Supply Warning The assembly of the unit must take place with the orientation diagrammed here 26 C6640 C6650...

Страница 29: ...Assembly dimensions C6650 Configuration with 24 VDC Power Supply optional Warning The assembly of the unit must take place with the orientation diagrammed here C6640 C6650 27...

Страница 30: ...61000 6 2 Emitted resistance according to EN 61000 6 4 Transport and storage The same values for atmospheric humidity and shock resistance are to be observed during transport and storage as in operat...

Отзывы: