Beckhoff C6640 Скачать руководство пользователя страница 3

 

Table of contents 

 

Table of contents 

1. 

2. 

3. 

4. 

General instructions 

3

 

Notes on the Documentation 

3

 

Liability Conditions 

3

 

Description of safety symbols 

3

 

Basic safety measures 

4

 

Operator's obligation to exercise diligence 

5

 

Operator requirements 

5

 

Product Description 

6

 

Appropriate Use 

6

 

Opening the Housing 

6

 

Configuration with 100-240 V

AC

 Full Range Power Supply 

8

 

Interfaces 9

 

PS/2 connections 

9

 

Serial interface 

9

 

Parallel interface 

9

 

VGA connection 

9

 

USB interfaces 

9

 

Network connection 10/100MBit 

9

 

Network connection 1Gbit (optional) 

9

 

Sound-On-Board 9

 

Additional plug-in cards (optional) 

9

 

Installation Instructions 

10

 

Transport and Unpacking 

10

 

Transport 

10

 

Unpacking 10

 

Installation of the PC in the control cabinet 

11

 

Earthing measures 

11

 

Power Supply Connection with 100-240 V

AC 

power supply unit 

12

 

Mains Socket 

12

 

Power supply cords 

12

 

Power Supply Connection with 24 V

DC 

 power supply unit (optional) 

13

 

Beckhoff power supply technology 

13

 

Electrical Data 

14

 

Pin assignment of the connectors 

14

 

Pin assignment power supply 

14

 

Pin assignment external wiring 

15

 

Fitting the Cables 

15

 

Fitting the connector 

15

 

Connecting Power Supply 

16

 

Cable Cross Sections 

16

 

Configuration for shutting down the PC 

16

 

PC_ON and Power Status functions 

16

 

UPS output 

16

 

UPS output function 

16

 

Wiring diagram 

17

 

Connecting devices 

18

 

Connecting cables 

18

 

Check voltage rating and connect. 

18

 

Operating Instructions 

19

 

Switching the Industrial PC on and off 

19

 

First switching on and driver installation 

19

 

Servicing and Maintenance 

20

 

Cleaning the Industrial PC 

20

 

Replacing the battery on the motherboard 

20

 

Replacing the fan 

20

 

Servicing 

21

 

 C6640, C6650 

Содержание C6640

Страница 1: ...Installation and Operating instructions for Control Cabinet Industrial PC C6640 C6650 Version 1 1 Date 2010 04 08...

Страница 2: ......

Страница 3: ...1 Earthing measures 11 Power Supply Connection with 100 240 VAC power supply unit 12 Mains Socket 12 Power supply cords 12 Power Supply Connection with 24 VDC power supply unit optional 13 Beckhoff po...

Страница 4: ...arters 23 Beckhoff Support 23 Beckhoff Service 23 Assembly dimensions 24 C6640 Configuration with 100 240 VAC Power Supply 24 C6640 Configuration with 24 VDC Power Supply optional 25 C6650 Configurati...

Страница 5: ...meaning of 443 BGB of the German Civil Code or a statement about the contractually expected fitness for a particular purpose in the meaning of 434 par 1 sentence 1 BGB In the event that it contains te...

Страница 6: ...he plant Pulling out the fieldbus connection plug uncouples the PC optional Items of equipment that have been switched off must be secured against being switched on again The Industrial PC s power sup...

Страница 7: ...al regulations depending on the machine type Depending on the type of machine and plant in which the Industrial PC is being used there will be national regulations for the control of such machines and...

Страница 8: ...applications Opening the Housing View of the C6650 configuration with 100 240 VAC power supply The housing cover is locked by a latch After pressing the key 1 the cover can be fold up a little in the...

Страница 9: ...ing cover Now the housing cover can be taken off completely so providing access to the components The reassembly of the cover takes place in reverse order Ensure that the cover engages into the slides...

Страница 10: ...configuration options of the motherboard are available Order option Intel Celeron M Intel Pentium M Intel Core Duo Intel Core 2 Duo Intel Core 2 Quad C6640 0000 1 5 GHz 1 8 GHz C6640 0010 2 0 GHz 2 1...

Страница 11: ...interfaces USB1 USB4 The four USB interfaces X108 X111 are used to connect peripheral devices with USB connections The USB2 0 standard is supported Network connection 10 100MBit Network 10 100MBit Th...

Страница 12: ...in temperature make sure that moisture condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur a d...

Страница 13: ...bove and below the housing must be at least 50 mm in order to ensure adequate ventilation of the PC Warning Extreme environmental conditions should be avoided as far as possible Protect the PC from du...

Страница 14: ...at the PC housing main switch mains socket Power supply cords Power cords Europe In the area Europe you use the provided cable with inlet connector for non heating apparatus to connect the Industrial...

Страница 15: ...ach addresses this problem and now offers the user the option of switching the PC off without the need for using the battery thereby reducing the load on the battery In addition to the main switch thi...

Страница 16: ...ower supply unit Current loading maximum 5 V 14 A 5 V 0 3 A 12 V 12 A 12 V 0 5 A 3 3 V 12 A 5 V VSB 1 5 A Pin assignment of the connectors Two 5 pin plug connectors with CAGE CLAMP connection see phot...

Страница 17: ...terials for assembly of the connector Female plug connector 5 pole Strain relief housing 1 2 3 4 5 A B C D Fitting the connector Fitting the connector to the cable The plug is fitted to the cable as f...

Страница 18: ...C_ON signal is inverted i e the PC shuts down if the 24 V connection is live If the PC_ON input is NOT connected by the user the PC can be booted in the familiar way by connecting the supply voltage a...

Страница 19: ...g to the wiring diagram the circuit of PC_ON and Power Status is symbolical Wiring diagram power supply and external switch i Note The battery pack can only be connected when the Industrial PC is prov...

Страница 20: ...ndustrial PC and to the devices that are to be connected Connect all data transfer cables if present to the appropriate plug in receptacles of the data telecommunication networks Reconnect all devices...

Страница 21: ...Warning First shut down then switch off the PC If the Industrial PC is switched off as the software is writing a file to the hard disk the file will be destroyed Control software typically writes som...

Страница 22: ...sion if battery is incorrectly replaced Replace only with same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Replacing the f...

Страница 23: ...Industrial PC On delivery of the Beckhoff Industrial PC with operating system the software is already installed Should the software not be installed on your PC the drivers can be installed from the dr...

Страница 24: ...d press any key Check the setup settings Call Beckhoff Service Computer boots software starts but control does not operate correctly Cause of the fault is either in the software or in parts of the pla...

Страница 25: ...tra e 5 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 e mail info beckhoff com Beckhoff Support Beckhoff offers you comprehensive technical assistance helping you not only with the ap...

Страница 26: ...sions The following pages show diagrams of the Industrial PC with dimensions in mm C6640 Configuration with 100 240 VAC Power Supply Warning The assembly of the unit must take place with the orientati...

Страница 27: ...Assembly dimensions C6640 Configuration with 24 VDC Power Supply optional Warning The assembly of the unit must take place with the orientation diagrammed here C6640 C6650 25...

Страница 28: ...Assembly dimensions C6650 Configuration with 100 240 VAC Power Supply Warning The assembly of the unit must take place with the orientation diagrammed here 26 C6640 C6650...

Страница 29: ...Assembly dimensions C6650 Configuration with 24 VDC Power Supply optional Warning The assembly of the unit must take place with the orientation diagrammed here C6640 C6650 27...

Страница 30: ...61000 6 2 Emitted resistance according to EN 61000 6 4 Transport and storage The same values for atmospheric humidity and shock resistance are to be observed during transport and storage as in operat...

Отзывы: