Installation Instructions
Power Supply Connection with 100-240 V
AC
power supply unit
Supplied mains power unit The Industrial PC is serially fitted with a 100-240 V
AC
, 50-60 Hz full range
power supply unit .
Current carrying capacity of
the 100-240 V power
supply unit
Output voltages from the 100-
240 V power supply unit
Current loading
maximum
+3.3 V
16 A
+5 V stand by
2 A
+5 V
25 A
-5 V
0.3 A
+12 V
13 A
-12 V
0.8 A
Mains Socket
A mains socket is located on side of the PC housing in order to connect the
power supply.
Mains socket at the PC
housing
mains socket
Power supply cords
Power cords Europe
In the area Europe you use the provided cable with inlet connector for non-
heating apparatus to connect the Industrial-PC to the power supply.
Power cords USA / Canada In the area USA / Canada the power supply cable must show the following
specifications according to the supply voltage:
Listed, Detachable, maximum 4.5 m (14.76 ft.) long; rated minimum 125 V,
10 A, Type SJT or Type SVT; one end terminates in NEMA 5-15P/-20P
grounding-type attachment plug, other end in appliance coupler
or
Listed, Detachable, maximum 4.5 m (14.76 ft.) long; rated minimum 250 V,
10 A, Type SJT or Type SVT; one end terminates in NEMA 6-15P/-20P
grounding-type attachment plug, other end in appliance coupler.