Technical data
Dimensions
C3620
Dimensions (W x H x D):
388 x 324 x 201 mm
Weight:
11.5 kg (basic configuration)
C3640
Dimensions (W x H x D):
470 x 348 x 199 mm
Weight:
14.1 kg (basic configuration)
Color
Display
C3620
Size, Resolution:
12“, 800 x 600 dpi
C3640
Size, Resolution:
15“, 1024 x 768 dpi
Do not use the PC in areas
of explosive hazard
The Industrial PC may not be used in areas of explosive hazard.
The following conditions must be observed during operation:
Environmental conditions
Ambient temperature:
0 to 55°C
Atmospheric humidity:
Maximum 95%, non-condensing
Shock resistance
Sinusoidal vibration:
(EN 60068-2-6)
10 to 58 Hz:
0.035 mm
58 to 500 Hz: 0.5 G (~ 5 m/ s
2
)
During reading of CD-ROM:
10 to 58 Hz:
0.019 mm
58 to 500 Hz: 0.25 G (~ 2.5 m/ s
2
)
Impact:
(EN 60068-2-27)
5 G (~ 50 m/ s²), duration: 30 ms
During reading of CD-ROM:
5 G (~ 50 m/ s²), duration: 11 ms
Protection class
Protection class:
Front side IP65, rear side IP20
Power supply with
100-240 V
AC
power supply
unit or 24 V
DC
power supply
unit (optional)
Supply voltage:
100-240 V
AC
50-60 Hz
Optional: 24 V
DC
(22
– 30 V
DC
)
Power consumption:
C3620-0020:
ca. 89 W
(for the basic version)
C3620-0030:
ca. 114 W
C3640-0020:
ca. 98 W
C3640-0030:
ca. 123 W
If operated with UPS:
additional 30 W (while charging)
Electromagnetic
Compatibility (EMC)
Interference resistance:
according to EN 61000-6-2
Emitted resistance:
according to EN 61000-6-4
Transport and storage
The same values for atmospheric humidity and shock resistance are to be
observed during transport and storage as in operation. The shock
resistance during transport can be improved by means of suitably packing
the Industrial PC. The ambient temperature during storage and transport
must be between -20°C and +65°C.
i
Note
Pixel errors in the TFT display are production-caused and represent
no complaint-reason!
Approvals
FCC: Federal Communications Commission
Radio Frequency Interference Statement
FCC Approval for USA
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his
own expense.
FCC: Canadian Notice
FCC Approval for Canada
This equipment does not exceed the Class A limits for radiated emissions as
described in the Radio Interference Regulations of the Canadian Department of
Communications.