Technical description
26
───
Version: 1.0
AX2090-BW65
7.1
Installation position
The approved installation position of the braking resistors is vertical
(A) or horizontal (B). In the vertical installation position the electrical
connection must point downwards.
Pay attention to the installation position
Due to heat generation the vertical installation position (A) is only
permitted if the electrical connection points downwards.
Failure to comply may result in damage to the connecting cable
and malfunctions.
7.1.1
Distances
You must maintain minimum distances, depending on the installa-
tion position.
In all installation positions:
• 25 mm to adjacent components or walls
• 200 mm upwards to components or roofs
In vertical installation position:
• 100 mm downwards to components or floor