For your safety
Version: 1.0
───
15
AMI8100
2.2.2
During operation
Do not work on live electrical parts
Never carry out any work on the motor or motor cable when they are
live. Measure the voltage on the DC link test contacts DC+ und DC-.
Only work on the motor when the voltage has dropped to < 50 V.
Ensure that the protective conductor is connected properly. Never
loosen electrical connections when live. Disconnect all components
from the mains and secure them against being switched on again.
Do not touch hot surfaces
Check the cooling of the surfaces with a thermometer. Do not touch
the components during and immediately after operation. Allow the
components to cool sufficiently after switching off.
Avoid overheating
Operate the servo drive according to the technically foreseen speci-
fications. Refer here to the chapter: "Technical data". Activate and
monitor the temperature contact of the servo drive. Provide for suffi-
cient cooling. Switch off the servo drive immediately if the tempera-
ture is too high.
Do not touch any moving or rotating components
Do not touch any moving or rotating components. Fasten all parts or
components on the machine or plant.
2.2.3
After operation
De-energize and switch off components before working on
them
Check the functionality of all safety-relevant devices. Secure the
working environment. Secure the machine or plant against being in-
advertently started up. Observe the chapter: "Decommissioning".
No direct skin contact with solvents or lubricants
In case of improper use, the solvents or lubricants used can lead to
skin irritations. Therefore, avoid direct skin contact.