15
Indicator LED’s
Basic Control Unit S80
MLS Professional Card
LED
Illustration
Indication
Meaning
POWER
+UB
on
Power supply connected
off
No power supply connected
UP
AUF
on
Door moves UP
DOWN
ZU
on
Door moves DOWN
LED
Illustration
Indication
Meaning
Pilot
Betr
on
Normal mode
contin. flash
Setting mode (dead-man mode)
In order to switch to normal mode (automatic), please push the pro-
gramming button
Prog
.
Fault1
Stör1
on
STOP button pressed, wicket door switch/spring break safety device
triggered or Emergency Stop transistor faulty
1 flash
Door running time exceeded
2 flashes
Pre-limit switch testing set too high
3 flashes
No switch pulse from the safety edge at the bottom end limit
4 flashes
Limit switch Up and Down activated simultaneously.
contin. flash
Internal communication fault or main processor faulty
Fault2
Stör2
on
Hardware test routine being processed
1 flash
Safety circuit of drive has been triggered
2 flashes
Safety edge actuated just before downward movement of door or
internal bottom rail sensor faulty
3 flashes
Slack rope switch/pull in cable safety/switch
4 flashes
Internal communication fault or monitoring processor faulty
5 flashes
The door has run up against an obstacle 5 times because automatic
closing is activated
6 flashes
The unit connected to system socket X1 is faulty
contin. flash
Photoelectric barrier actuated
USA
USA
on
Safety edge actuated
off
Safety edge not actuated
VES
VES
on
Pre-limit switch actuated
off
Pre-limit switch not actuated
Sonder
Sonder
off
DIP switch released/control times unchanged
1 flash
DIP switch inhibited/control times unchanged
2 flashes
DIP switch released/control times changed
on
DIP switch inhibited/control times changed