background image

Becker-Antriebe GmbH
35764 Sinn/Germany
www.becker-antriebe.com

P3/30PS - P9/16PS 

Assembly and Operating Instructions 

Tubular drives for sunshades

en

Important information for:

 

Fitters

• Electricians
• Users
Please forward accordingly!
These instructions must be kept for future reference.

Содержание P9/16PS

Страница 1: ...www becker antriebe com P3 30PS P9 16PS Assembly and Operating Instructions Tubular drives for sunshades en Important information for Fitters Electricians Users Please forward accordingly These instru...

Страница 2: ...ectronics using end stop systems No need to adjust end limits changes to canopies curtains are automatically compensated for using the end stop systems Safety shutdown in accordance with European engi...

Страница 3: ...ided injuries may result Important safety instructions for the user Caution Failure to observe these instructions can lead to serious injuries All operational work including maintenance and cleaning o...

Страница 4: ...cts or modifications which have not been agreed with or approved by us are prohibited We do not accept liability for damages or injury arising from such actions Before installation shut down all lines...

Страница 5: ...cket Please observe the following when assembling the drive Assembly of the drive adapter with locking device You can see how to insert the locking device from its shape When insert ing the locking de...

Страница 6: ...vant ring A and drive adapter B Insert the tubular drive with the pre assembled ring and drive adapter into the tube as shown Ensure that the ring and drive adapter are correctly positioned in the tub...

Страница 7: ...le leads of the tubular drive to those of the switch control set product no 4901 002 181 0 or of the operator s control according to the colour coding and switch on the power supply a Point when canop...

Страница 8: ...f automatically The end limits are set Deleting the end limits using the switches a Deleting the end limits individually Note Itisonlypossibletodeleteanindividuallimitstopifthepointwhen the canopy is...

Страница 9: ...both switches to the program ming position Move the canopy to the required end limit when the canopy is extended 2 Press the programming button 1 of the setting controls for 3 seconds This is acknowl...

Страница 10: ...tion Move the canopy to the required end limit when the canopy is extended 2 Press the programming button 1 of the setting controls for 3 seconds This is acknowledged by a click of the tubular drive T...

Страница 11: ...clack sound to confirm The final position has been deleted b Deleting both final positions Move the canopy to the final position which is to be deleted Move the canopy to a position be tween both fin...

Страница 12: ...he changeover time for changing the running direction must be at least0 5 s Switch and control must not execute simultane ous UP and DOWN commands To operate drives with electronic limit switching onl...

Страница 13: ...ain after a few minutes 2 Tubular drive is faulty does not work even after standing still for a long period of time 2 Replace the drive carry out RESET with the programming pushbutton No click may be...

Страница 14: ...perating Instructions Sample wiring diagrams Controlling one several drive s via a single switch button Central group and individual control using Centronic UnitControl UC42 Subject to technical chang...

Страница 15: ...15 Declaration of conformity...

Страница 16: ...2010 300 246 0f 03 12...