9
Caution
The switch control set is not designed for permanent use, but
only for initial operation.
Connect the flexible leads of the tubular drive to those of the setting controls
(product no. 4935 200 011 0) according to the colour coding and switch on the
power supply.
Action
Reaction
Setting the end limits using the setting controls
a) Point when canopy is extended to point when canopy is retracted with-
out end stop
Note
When the end limits are set using this method, no adjustment is
made for the length of the canopy.
Move both switches to the program-
ming position.
Move the canopy to the required end
limit when the canopy is extended (2).
Press the programming button (1) of
the setting controls for 3 seconds.
This is acknowledged by a click of the
tubular drive.
Then move the canopy to the required
end limit when retracted (2).
Now press the programming button (1)
of the setting controls for 3 seconds.
This is acknowledged by a click of the
tubular drive.
The end limits are set.
Note
If the tubular drive switches off prematurely because it encounters an obstacle, it is possible to release
this obstacle by briefly moving the canopy in the opposite direction, removing the obstacle and then mov-
ing the canopy up or down again to set the new end limit.