Technical data dia. 58
Tubular drive
L60-11
L80-11
L100-11
Model
M04a
Type
C M A
Rated torque [Nm]
60
80
100
Output speed [rpm]
11
11
11
Limit switch range
36 revolutions
Supply voltage
240 V AC / 50 Hz
Connected load [W]
250
310
450
Rated current consumption [A]
1.05
1.30
1.95
Operating mode
S2 4 min
Degree of protection
IP 44
Min. tube inside diameter [mm]
60
Emission sound pressure level [dB(A)]
≤ 70
Certificate of Suitability
Certificate No.: SAA181406
What to do if...?
Problem
Cause
Remedy
The roller shutter curtain is raised un-
evenly or not at all.
1.
One or more attachments have
broken off.
2.
Lath has broken off.
Repair system; then reset the limit posi-
tions.
Tubular drive stops arbitrarily; cannot be
restarted in the same direction.
Roller shutter curtain keeps sticking; too
much friction.
Repair system
Tubular drive does not run in the right dir-
ection.
Electrical connection faulty.
Check the electrical connection.