Information for the electrician
The tubular drives with mechanical limit switching must
not
be connected in parallel. The drive manufacturer offers a range of suit-
able controls for the simultaneous control of several drives.
Use external conductor L1 to control the up and down direction. Other devices or consumers (lamps, relays, etc.) must not be dir-
ectly connected to the drive connecting cables. For this purpose, the drives and additional devices must be decoupled by relay
controls.
When installing the drive, all-pole disconnection from the mains with a contact gap of at least 3 mm per pole must be provided.
Attention
Only use mechanically or electrically locked switching elements with a marked zero posi-
tion! This also applies when drives with electronic and mechanical limit switching are used
in the same system. The changeover time for switching the running direction must be at
least 0.5 s. The switch and control must not execute simultaneous UP and DOWN com-
mands. Protect the electrical connections from damp.
Once you have finished wiring everything to the control, ALWAYS check the right direction
assignment of the drive to the control buttons UP and DOWN, EXTEND and RETRACT.
If the drive is to be operated with devices which contain sources of interference, the elec-
trician must ensure suitable interference suppression for the relevant devices.
Disposal
This product is made of various materials which must be disposed of properly. Find out about the applicable regulations on recyc-
ling or disposal for this product in your country.
The packaging material must be disposed of properly.
Maintenance
These drives are maintenance-free.
Technical data dia. 35
Tubular drive
P4-30
Model
M04a
Type
C M A
Rated torque [Nm]
4
Output speed [rpm]
30
Limit switch range
38 revolutions
Supply voltage
240 V AC / 50 Hz
Connected load [W]
110
Rated current consumption [A]
0.45
Mode
S2 4 min
Degree of protection
IP 44
Min. tube inside diameter [mm]
37
Emission sound pressure level [dB(A)]
≤ 70
13